Installing and connecting the drain hose of the indoor unit

AA
Indoor unit
Drain hose
The drain hose must not
be bent.
Drain hose installation
1. If necessary, connect the 2-meter extension drain hose to the drain hose.
2. If you use the extension drain hose, insulate the inside of the extension drain hose with a shield.
3. Fit the drain hose into 1 of 2 drain hose holes, then fix the end of the drain hose
tightly with a clamp.
4. Pass the drain hose under the refrigerant pipe, keeping the drain hose
tight.
5. Pass the drain hose through the hole in the wall. Check if it slants
downwards as seen in the picture.
Inadequate installation may cause condensate water leakage.
Drain hose connection must be easy accessible and serviceable.
10
slant upwards.
5cm
less
Keep a clearance of at least
5cm between the end of the
drain hose and the ground.
be placed under water.
Ditch
Do not place the end of the
drain hose in a hollow.
Shield
Drain hose
Drain hose hole

Advertisement