41-3
Purpose
Operation test/check
Function (Purpose) Used to check the operations of the docu-
ment size sensor and the control circuit.
Section
Operation/Procedure
The detection output level (A/D value) of OCSW and the document
sensor (PD1 - PD7) is displayed in real time.
The light receiving range of PD1 - PD7 is 1 - 255. (Default: 128)
Item/Display
Content
OCSW
Original cover SW
PD1
Document detection 1
PD2
Document detection 2
PD3
Document detection 3
PD4
Document detection 4
PD5
Document detection 5
PD6
Document detection 6
PD7
Document detection 7
43
43-1
Purpose
Setting
Function (Purpose) Used to set the fusing temperature in each
mode.
Section
Operation/Procedure
1)
Select an item to be set with scroll keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
26cpm machine
Item/Display
A
HL_UM READY
B
HL_US READY
C
HL_UM PLAIN PAPER BW
D
HL_US PLAIN PAPER BW
E
WARMUP FUMON HL_UM T
F
WARMUP FUMOFF HL_UM T
G
WARMUP END TIME
H
HL_UM HEAVY PAPER
I
HL_US HEAVY PAPER
J
HL_UM OHP PAPER
K
HL_US OHP PAPER
L
HL_UM E-STAR
M
HL_US E-STAR
N
HL_UM PRE-JOB
O
HL_UM WARMUP_120L
P
HL_US WARMUP_120L
Q
LO_WARMUP_TIME
R
HL_UM WARMUP_120H
S
HL_US WARMUP_120H
Detection level range
0-1 ("1" to Close)
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
Content
Ready standby TH_UM set value
Ready standby TH_US set value
Black-White plain paper TH_UM
set value
Black-White plain paper TH_US
set value
Fusing motor pre-rotation start
TH_US set value
Fusing motor previous rotation
complete time
Warm-up complete time
Heavy paper TH_UM set value
Heavy paper TH_US set value
OHP-TH_UM set value
OHP-TH_US set value
Preheating TH_UM set value
Preheating TH_US set value
TH_UM set value when recovery
from Warm-Up
TH_UM set value when Warm-Up
at 120C or below
TH_US set value when Warm-Up
at 120C or below
O, P applying time (Timer from
completion of Ready)
TH_LM set value when Warm-Up
at 120C or above
TH_US set value when Warm-Up
at 120C or above
MX-M264U SIMULATION 6 – 35
Setting
Group A
Group B
range
SW-A
SW-B
SW-A
70 - 220
175
175
175
70 - 220
170
170
170
70 - 220
175
180
175
70 - 220
175
180
175
0 - 200
0
0
0
0 - 60
0
0
0
0 - 20
18
18
18
70 - 220
190
70 - 220
190
70 - 220
175
70 - 220
175
70 - 220
95
95
95
70 - 220
95
95
95
70 - 220
130
175
175
70 - 220
130
175
175
70 - 220
130
170
170
0 - 255
0
0
0
70 - 220
130
175
175
70 - 220
130
170
170
Default value
Group C
SW-B
SW-A
SW-B
SW-A
175
180
180
180
170
175
175
175
180
185
190
185
180
185
190
185
0
0
0
0
0
0
0
0
18
18
18
18
190
190
190
190
175
185
175
185
95
95
95
95
95
95
95
95
175
175
175
175
175
175
175
175
170
170
170
170
0
0
0
0
175
175
175
175
170
170
170
170
Group D
SW-B
180
175
190
190
0
0
18
190
190
185
185
95
95
175
175
170
0
175
170