Panasonic TH-65PF20W Service Manual page 11

High definition plasma display
Hide thumbs Also See for TH-65PF20W:
Table of Contents

Advertisement

GPF13D chassis series have special function and operation setting facility called Option Menu. This Option Menu is useful
for special function required customers. This should be set at the installation stage.
Option menus
Weekly Command Timer
Audio input select
Onscreen display
Initial INPUT
Initial VOL level
Maximum VOL Level
INPUT lock
Button lock
Remocon User Level
Off-timer function
Initial Power Mode
ID select
Remote ID
Serial ID
Display size
Studio W/B
Studio Gain
Slot power
Power On Screen Delay
Clock Display
All Aspect
Auto Setup
Rotate
Note:
When both main unit buttons and remote control are disabled due to the [Button lock], [Remocon User level] or [Remote ID]
adjustments, set all the values [Off] so that all the buttons are enabled again.
Press the [Volume down] button on main unit together with [R] button on the remote control and hold for more than 5 seconds.
The [SHIPPING] menu is displayed and the lock is released when it disappears.
Option Menu for GPF13D series
default setting
---
Sets Weekly Command Timer.
---
Set up the sound when an image input is selected.
On
Enable/Disable to display input mode indication after power on and no signal
indication.
Off
Sets the initial input mode when the power is turned on. Allow input mode selec-
tion while power is on.
Off
Sets the initial volume level when the power is turned on. Allow Volume control
while power is on.
Off
Sets the maximum volume to desired level. Volume cannot exceed this level.
Off
Fixes the input mode to AV, Component/RGB or PC. Can not change input
mode by input selection key.
Off
Enable/Disable bottom operation buttons (Input, Menu, Enter and/or volume up/
down)
Off
Remote key invalidation.
Off: Valid key is all key of remote.
User1: Valid key are only Stand-by (ON/OFF), Input, Direct input, Picture, Sur-
round, Sound mute On/Off, and volume adjustment.
User2: Valid key is only Stand-by (ON/OFF).
User3: All keys are null and void
Enable
Off-timer operation Enable/Disable.
Normal
Sets the power mode of the unit for when the power recovers from failure or
after plugging off and in again.
0
Set ID number from 0 to 100.
Off
Remote ID function On/Off.
(While the Remote ID on, standard remote function can not control the unit.)
Off
Serial ID function On/Off
Off
Display size function On/Off
Off
Studio W/B function On/Off
Off
Studio Gain function On/Off
Off
Sets the slot power mode while the power is turned on.
Allow Optional Terminal Board insert Slots while power is on.
Off
You can set the power-on delay time of the displays to reduce the power load,
when you press
example, on MULTI DISPLAY system.
Set each display's setting individually.
Off
Clock Display function On/Off.
Default
Aspect mode: default/All aspect mode.
Manual
Sets the operational mode of the automatic position adjustment in the POS./
SIZE menu.
Off
Rotate function On/Off
Contents
to turn on the multiple displays that are set together, for
11
TH-65PF20W / TH-65PF20T

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th-65pf20t

Table of Contents