Pump; Flow-Meter; Water Sensor Control Board - Philips HD 8753 Service Manual

Intelia
Table of Contents

Advertisement

INTELIA
7.9.

Pump

A
C
A
Disconnect the water circuit connections (A) and
electrical connections (B), loosen the safety valve
D
(C) and slide the pump off the brackets (D).
B
D
A

7.10. Flow-meter

7.11. Control board

7.12. Water sensor control board

Slide the card off the
support.
Saeco International Group
Lift the fl ow meter out of the casing assembly and
remove the electrical and water circuit connections.
Loosen the screws as
illustrated, slide out the
electrical connection and
remove the card guard.
Slide out the pipe
connecting the fl ow
meter to the pump.
Loosen the screw as illustrated and
remove the capacitive sensor glued to
the seat.
Rev. 01 / September 2011
07 DISASSEMBLY
Slide the card off the
support and disconnect the
electrical connections.