Steamout - Philips HD 8753 Service Manual

Intelia
Table of Contents

Advertisement

INTELIA
5.2.

SteamOut

To enter Test Mode
1.
Hold down the Espresso and
Menu buttons
2.
Switch on the main switch at
the back of the machine
This procedure is carried out whenever you need to completely empty the residual water from
This procedure is carried out whenever you need to completely empty the residual water from
the boiler.
the boiler.
It is recommended to carry out the SteamOut when the machine is used in places
It is recommended to carry out the SteamOut when the machine is used in places
where the temperature could freeze the water inside the machine
where the temperature could freeze the water inside the machine
Saeco International Group
When the machine is switched on the procedure starts; the display changes
When the machine is switched on the procedure starts; the display changes
to yellow and the word "ON" indicates that the procedure is running.
to yellow and the word "ON" indicates that the procedure is running.
During the procedure the 2-way solenoid valve remains open and the
During the procedure the 2-way solenoid valve remains open and the
steam is discharged.
steam is discharged.
Caution!!!
Caution!!!
If the dreg drawer is not fully in, the machine will ask you to insert it, this
If the dreg drawer is not fully in, the machine will ask you to insert it, this
must be done otherwise the 2- and 3-way solenoid valves are not powered.
must be done otherwise the 2- and 3-way solenoid valves are not powered.
Caution!!!
Caution!!!
If the side hatch opens, the machine warns you to close it, the hatch must
If the side hatch opens, the machine warns you to close it, the hatch must
be closed otherwise the 2- and 3-way solenoid valves will not be powered.
be closed otherwise the 2- and 3-way solenoid valves will not be powered.
When the procedure is completed, the message "COMPLETE" appears on
When the procedure is completed, the message "COMPLETE" appears on
the display, the solenoid valves close automatically and the machine may
the display, the solenoid valves close automatically and the machine may
be switched off.
be switched off.