INTELIA
5.3.
Error codes
ERROR
ERROR
CODES
CODES
The coffee grinder is blocked (grinder blades jammed or sensor not
01
01
reading properly)
The brewing unit is blocked in work position (microswitch not released
03
03
in up position after 3", torque error trying to move down, descent time
out exceeded)
The brewing unit is blocked in home position (microswitch not released
04
04
in down position after 3", torque error trying to move up, ascent time
out exceeded)
Water circuit / fl ow meter problems (water circuit blocked or no fl ow
05
05
meter signal)
Boiler temperature sensor short circuited
10
10
11
11
Boiler temperature sensor open circuit
The boiler temperature has exceeded the maximum allowed value
14
14
(165°c)
The boiler temperature has not increased by x°C in y sec (boiler power
15
15
supply disconnected, incorrect boiler fi tted must be a 1300W boiler, par-
tial power supply to boiler, cut out thermostat tripped)
19
19
Mains voltage trouble