Superior™ DRT2000 and DRC2000 Direct-Vent Gas Fireplaces
Table 11: Fireplace Framing Specifications
Model
A *
DRC2033 /
33 3/4
DRT2033
857
DRC2035 /
35 3/8
DRT2035
899
DRC2040 /
40 3/8
DRT2040
1026
DRC2045 /
45 3/8
DRT2045
1153
C = Minimum height of top vent installations
E = Minimum height of rear vent installations
* Minimum opening size; additional 1/8" per side is recommended.
NOTE: Framing specifications do NOT apply for flexible venting.
When using flexible venting, refer to the kit requirements for
framing specifications.
NOTE: See Page 28 concerning use of compact terminations on
rear-vent 45" Models.
Table 12: Fireplace Framing Specifications—Corner Installation with Horizontal Termination
Model
A
B
33 3/4
51 1/4
DRC/T2033
857
1302
35 3/8
59 1/2
DRC/T2035
899
1511
40 3/8
63 13/16
DRC/T2040
1026
1621
45 3/8
70 3/8
DRC/T2045
1153
1788
Table 13: Fireplace Specifications
K
L
N
Top View
Model
E
DRC2033 / DRT2033 30 1/8 (765) 26 1/4 (667) 18 5/16 (465)
DRC2035 / DRT2035 32 1/8 (816) 28 3/4 (730)
DRC2040 / DRT2040 37 1/8 (943) 33 1/4 (845)
DRC2045 / DRT2045
37 1/8 (943
B
C
D
34 1/4
36 7/8
14 1/2
870
930
368
36 1/4
38 3/4
18
921
984
447
41 1/4
43 3/4
18
1048
1111
447
41 1/4
43 3/4
18
1048
1111
447
C
D
E
5 1/2
36 1/4
25 5/8
12 1/8
140
921
651
308
6 5/8
42 1/16
3. 1/4
14 1/4
168
1068
768
362
8 1/2
45 11/32
32 3/16
15 7/8
216
1152
818
403
10 1/4
49 3/4
35 1/4
17 1/2
260
1264
895
445
NOTE: When finishing the area around the hood, 5/8" clearance above hood is required for hood installation.
O
H
E
Front View
F
G
H (door)
30 1/2 (775)
22 1/4 (565)
32 3/8 (822)
27 1/4 (692)
37 3/8 (949)
33 1/4 (875)
27 1/4 (692)
42 3/8 (1076)
E
NOTE: Dimension "D" is the
required framing depth when
19 5/8
499
the finish material (drywall)
thickness is 1/2" (13mm).
23 3/8
594
Vent Framing—Top Vent
with One 90° Elbow
28 1/4
717
28 1/4
717
B
Inches (millimeters)
F
G
14 1/2
368
18
457
18
457
C
18
457
Back wall of chase/enclosure (including finishing materials)
J
G
F
Blower
access panel
M
J
K
33 5/8 (854)
21 7/8 (556) 10 15/16 (278)
35 1/4 (895)
25 (635)
40 1/4 (1022)
30 (762)
45 1/4 (1149)
35 (889)
10 1/2
(267)
5 1/8
(130)
C
E
D
1/2 A
A
E
F*
G
A
B
Hood
Junction
box access
Gas line
access
Left Side View
Right Side View
L
M
31 (787)
12 1/2 (317)
32 7/8 (835)
15 (381)
37 7/8 (962)
17 1/2 (445)
42 7/8 (1089) 10 1/16 (256)
Installation
900004-00, 04/2015
Framing
construction to be
2 x 4, or larger.
7 (178)
12 1/8
(308)
7
(178)
D
Inches
(millimeters)
N
O
8 1/2 (216)
14 (356)
10 1/16 (256)
17 (432)
10 1/16 (256)
17 (432)
17
17 (432)