DELIVERY

Marsal & Sons, Inc. cannot assume responsibility for loss or damage suffered in transit. The
carrier assumed full responsibility for delivery in good order when the shipment was accepted.
We are, however, prepared to assist you if filing a claim is necessary.

OVEN LOCATION

The oven should be installed in a location in which the facilities for ventilation permit satisfactory
combustion of gas and proper venting. The oven should be located so as not to interfere with
proper circulation of air within the confined space. In buildings where normal infiltration does
not provide the necessary air, outside air should be introduced.
It is essential that an adequate air supply to the oven be maintained to provide a sufficient
flow of combustion and ventilation air.
• Place the oven in an area that is free of drafts.
• Do not place the oven on a curb base or seal to a wall. This will restrict the flow of air and
prevent proper ventilation. Pilot outages or yellow, floating flames on the main burners
are indicative of a lack of secondary air.
Before making any utility connections to this oven, check the rating plate to be sure the oven
specifications are compatible with the gas and electrical services supplied for the oven. The
rating plate is located on the inside of the control door.

ADJUSTMENTS ASSOCIATED WITH INITIAL INSTALLATION

Each oven, and its component parts, have been thoroughly tested and inspected prior to
shipment. However, it is often necessary to further test or adjust the oven as part of a normal
and proper installation. These adjustments are the responsibility of the installer, or dealer.
Since these adjustements are not considered defects in material or workmanship, they are not
convered by the Original Equipment Warranty. They include, but are not limited to:
• calibration of the thermostat
• adjustment of the doors
• burner adjustments
• leveling
• testing of gas pressure
• tightening of fasteners
No installation should be considered complete without proper inspection, and if necessary,