Download Print this page

Sony RM-B150 Operation Manual page 30

Sony rm-b150 remote control unit for cameras
Hide thumbs Also See for RM-B150:

Advertisement

Settings on the RM Configuration Menu
Category
Subcategory Item
RM Diag
System
DIP SW
Pnl Test
Version
Preset
12 (E)
Detail Menu (Continued)
Display
COM
[OK], Sens, Open
- - - -, [CHU], CCU, CNU Shows the connected device.
Obj
On, [Off]
S1-1
On, [Off]
S1-2
On, [Off]
S1-3
S1-4
On, [Off]
S1-5
On, [Off]
On, [Off]
S1-6
On, [Off]
S1-7
S1-8
On, [Off]
AllReset
Contents
Shows the communication status of the command port
(CAMERA connector).
OK: Normal
Sens: Communication is not possible.
Open: No connector connected.
- - - - : None
CHU: Camera head
CCU: Camera control unit
CNU: Camera network unit
Shows DIP switch S1-1 status (S1=CPU-266 board S1).
Shows DIP switch S1-2 status (S1=CPU-266 board S1).
Shows DIP switch S1-3 status (S1=CPU-266 board S1).
Shows DIP switch S1-4 status (S1=CPU-266 board S1).
Shows DIP switch S1-5 status (S1=CPU-266 board S1).
Shows DIP switch S1-6 status (S1=CPU-266 board S1).
Shows DIP switch S1-7 status (S1=CPU-266 board S1).
Shows DIP switch S1-8 status (S1=CPU-266 board S1).
Executes the panel test.
To set the unit in Test mode, push the CANCEL/ENTER
switch towards ENTER with this subcategory selected ("Pnl
Test" displayed).
In Test mode, the test of switches, LEDs and volumes can
be made.
To release Test mode, push the RM Configuration switch in
the 4 direction while holding the CANCEL/ENTER switch at
ENTER.
Displays the version information.
To display the information, push the CANCEL/ENTER
switch towards ENTER with this subcategory selected
("Version" displayed).
The ROM version of this unit is displayed (The display can
be scrolled with the menu select knob).
To cancel the version display, push the CANCEL/ENTER
switch towards CANCEL.
Returns (resets) all the settings made by the RM
Configuration menu to the factory settings.
Operation procedure:
1. Push the RM Configuration switch in the $ direction with
this subcategory selected ("AllReset" displayed) while
holding the CANCEL/ENTER switch at ENTER.
"AllReset" flashes on the display.
2. Push the CANCEL/ENTER switch towards ENTER.
"OK?" flashes on the display.
3. Push again the CANCEL/ENTER switch towards
ENTER.
Reset is executed.
When reset is completed, "Complete" appears for several
seconds.
By pushing the CANCEL/ENTER switch towards CANCEL
in step 3, the reset operation can be canceled.

Hide quick links:

Advertisement

loading