Outdoor Unit - Toshiba RAV-SP560AT-E Service Manual

Split type
Hide thumbs Also See for RAV-SP560AT-E:
Table of Contents

Advertisement

14-2. Outdoor Unit

RAV-SM560AT-E (A02-014)
No.
Part name

Common
procedure
1. Detachment
1) Stop operation of the air conditioner, and
2) Remove the valve cover.
3) Remove wiring cover (ST1T Ø4 x 10L, 2
4) Remove the upper cabinet.
2. Attachment
1) Attach the waterproof cover.
2) Attach the upper cabinet.
3) Perform cabling of connecting cables, and
4) Attach the wiring cover.
5) Attach the valve cover.
Procedure
CAUTION
Never forget to put on the gloves at
working time, otherwise an injury will be
caused by the parts, etc.
turn off the main switch of the breaker for
air conditioner.
(ST1T Ø4 x 10L, 1 pc.)
• After removing screw, remove the valve
cover pulling it downward.
pcs.), and then remove connecting cable.
(ST1T Ø4 x 10L, 2 pcs.)
• After taking off screws, remove the
upper cabinet pulling it upward.
CAUTION
Be sure to attach a waterproof cover.
If it is not attached, there is a possibility
that water enters inside of the outdoor unit.
(ST1T Ø4 x 10L, 2 pcs.)
• Hook the rear side of the upper cabinet
to claw of the rear cabinet, and then put
it on the front cabinet.
fix with cord clamp.
(ST1T Ø4 x 10L 3 pcs.)
(ST1T Ø4 x 10L, 2 pcs.)
(ST1T Ø4 x 10L, 1 pc.)
• Insert the upper part of the upper
cabinet, set hooking claw of the valve
cover to the slit (at three positions) of the
main body, and then attach it pushing
upward.
– 187 –
RAV-SM560AT-E
Remarks
Valve
cover
Wiring
cover
Upper cabinet
Water-proof
cover
Cord clamp
Rear cabinet
Claw