Clear Restriction Group Of Item B; Clear All Restriction Of Item B; Assign Special Calling-Out Number; Assign Special Calling-Out Number For Class 0 - C-Tel CPS-Z User Manual

Group telephone system
Table of Contents

Advertisement

3.11.5 Clear Restriction Group of Item B

Format: 42 Q #
Explanation: Q: The group series from 01 to 16.
Description: to clear the call-out restriction of certain numbers of group Q.

3.11.6 Clear All Restriction of Item B

Format: 4 2 #
Description: to clear all the call-out restriction of certain numbers of item B

3.12 Assign Special Calling-out Number

3.12.1 Assign Special Calling-out Number for Class 0

Format: 4 3 P ABCD#
Explanation: ABCD: the initial digits of the calling number to be locked, it can be from 1-digit to 4-digits, it should be
P --- The group series from 01 to 16.
Description: Permit to dial the phone numbers starting with <ABCD> only.
Example: Ext.15 is be assigned dialing-out class 0, now you want Ext.15 can dial the numbers with initial digits –
0592,179
1. 16 groups of initial digits can be set.
2. This function only work for dialing-out class 0.

3.12.2 Clear Permission of Certain Group

Format: 43P #
Explanation: P: The group series from 01 to 16.
Description: to cancel the permission of certain calling-out numbers of group P

3.12.3 Clear All Permission

Format: 4 3 #
Description: to cancel all the permission of special calling-out numbers.
ended with # if less than 4-digits.