Current Consumption; The Countermeasure For "System Error - Casio EX-S100 Service Manual & Parts List

Hide thumbs Also See for EX-S100:
Table of Contents

Advertisement

(1) Current consumption (DC in = 3.70 ~ 4.05 [V])
• Make sure that current consumption is less than 300 mA in PLAY mode.
• Make sure that current consumption is less than 400 mA in REC mode.
• Make sure that current consumption is less than 1 mA when power is turned OFF.
(2) The battery indicator changes according to the voltages as follows.
• DC in = less than 3.67 ± 0.02V:
• DC in = less than 3.57 ± 0.02V:
• DC in = less than 3.40 ± 0.02V:

THE COUNTERMEASURE FOR "SYSTEM ERROR"

System error may occur when the battery is removed while data is written to the internal memory.
PROCEDURE
1. Initialize the system.
a) Enter the TEST mode.
b) Select "7:ROM UPDATE" and press SET button.
c) Next, select "5:SYSTEM INITIAL" and press SET button.
d) The following message appears.
SYSTEM INITIALIZE
START ...
PUSH OK KEY?
e) Press SET button and System is initialized.
"SUCCESS !" appears on the monitor.
2. Write firmware.
Refer to the "1. To update the firmware version" on page 7.
Write the firmware.
If the TEST mode boots automatically, change "USB TCC ON" to "USB TCC OFF".
Replace the Main PCB if the camera does not recover.

CURRENT CONSUMPTION

(PLAY mode)
(PLAY mode)
(PLAY mode)
— 18 —

Advertisement

Table of Contents
loading

Table of Contents