5.10 Failure Information

Displays failures such as Over Voltage, Over Load or Short Circuit.
(automatic reset when the fault is corrected).
5.11 Parameters
The first screen displays the type, software version and serial number
of the remote meter.
The second screen allows modification of
Switch-Pages (refresh time interval of the monitoring pages,
default 0 seconds)
Backlight duration (default 20 seconds).
Audible alarm ON/OFF (default OFF).

6 Technical Specifications

Self-consumption
Faceplate dimensions
Frame dimensions
Connector type
Cable length
Weight
Ambient Temperature
7 RS-485 connector pinout:
Pin No.
1
Power: +12V
2
RS485 B
3
RS485 A
4
GND
5
GND
6
RS485 A
7
RS485 B
8
Power: +12V
backlight and acoustic alarm on max. 65mA
Backlight on max. 23mA
Backlight off max. 15mA
98 × 98 mm / 3.86 × 3.86 inch
114 × 114 mm / 4.49 × 4.49 inch
RJ45
Max. 20 m
0.2 Kg
-20° C~+70° C / -4° F~158° F