RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
Carefully supervise children in the
same room as appliance.
If small children are present in the home, it
is recommended that this appliance be fitted
with a Firescreen kit. See Page 20 for ordering
information.
WARNINGS
Listed to standards:
ULC-S610 & UL-127
Report No. 304-7213
EPA Cert. No. 609
INSTALLATION AND

OPERATION INSTRUCTIONS

MONTECITO ESTATE™
EPA Wood-Burning Fireplace
P/N 850,038M REV. C 04/2007
MODEL
MONTEST
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and
understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circum-
stances. Any modification or alteration of the fireplace system, including
but not limited to the fireplace, chimney components and accessories,
may void the warranty, listings and approvals of this system and could
result in an unsafe and potentially dangerous installation.
Lennox™ wood-burning fireplaces are designed for use as a supple-
mental heater. They are not intended for continuous use as a primary
heat source.
The fireplace cannot be operated without a door.
Consult your dealer to select the correct door
model.
Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
Install the fireplace only as described in these
instructions.
PIMONTEST REV. 1
WARNINGS
TM

Advertisement

Table of Contents
loading

Summary of Contents for Lennox MONTECITO ESTATE MONTEST

  • Page 1: Operation Instructions

    RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNINGS • Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appli- ance. Severe burns may result. •...
  • Page 2: Safety Rules

    IMPORTANT! GENERAL SAFETY PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY RULES BEFORE YOUR FIRST FIRE. WARNING Never leave children unattended when there is a fire burning in the fireplace. IMPORTANT When burning wood, use SOLID NATURAL DRY WELL-SEASONED WOOD ONLY. Hardwoods are recommended (soft woods tend to burn very quickly).
  • Page 3: Table Of Contents

    CONGRATULATIONS! In selecting this LENNOX wood-burning appliance you have chosen one of the finest fireplaces available. The Montecito Estate™ is a clean burning EPA certified fireplace that is designed to provide you dependable service as well as warmth and enjoyment for many years to come.
  • Page 4: Combustion Control

    COMBUSTION CONTROLS Primary Air & Air Boost Controls There is no flue damper in the Montecito Es- tate™. As is common with air tight appliance, the combustion air control sets the flow of air entering the firebox. This allows for a more precise control of the fire.
  • Page 5: Refueling For Best Performance

    Slow Combustion When the air combustion control is completely closed, the fireplace is in a slow combustion phase. If the hearth is hot enough, slow com- bustion will not extinguish the fire, but there will be a noticeable change in the flame pattern. The flames will be slow and may appear dirty if the wood is too wet (moisture content of 20% and more).
  • Page 6: Important Cautions

    IMPORTANT CAUTIONS A. Do not block the hot air vents to the fire- place as this will cause the fireplace to overheat. B. Never use gasoline, kerosene, charcoal lighter fluid or similar liquids to start or rekindle a fire in this fireplace. Keep all such liquids well away from the fireplace at all times.
  • Page 7: Door Installation

    DOOR INSTALLATION The doors must be put in place only when the installation of the Montecito Estate™ is completed. All you have to do is fit the male part of the hinge, already on the door, to the female part, which is on the fireplace. To remove the doors, simply pull them up from the hinges.
  • Page 8: Fireplace Installation

    FIREPLACE INSTALLATION Locating The Montecito Estate™ The best location to install your fireplace is determined by considering the location of windows, doors, and the traffic flow in the room where the fireplace is located, allowing space in front of the unit for the hearth extension and the mantel, and taking into consideration the location of the hot air ducts (optional), outside air kit and chimney.
  • Page 9 Header Fireplace Framing 2” x 3” Min. Plywood 7’ Min. Rough Framing Face (unfinished shown) FRAMING DIMENSIONS Fireplace Opening Width 46-3/8” 1178 mm 49-1/2” 1257 mm 42-3/4” 1086 mm 20-7/8” 530 mm 93-7/8” 2384 mm 26-1/4” 47” 1194 mm 27-3/4” 705 mm 66-3/8”...
  • Page 10: Hot Air Ducting Installation

    FACING IMPORTANT The facade must be removable once installed. The facade is designed to overlap any facing material installed on the front of the fireplace. If thicker material is installed, use the facade as a template and make sure it can be easily removed for servicing.
  • Page 11 Frame Grill Figure 16 When installing the double outlet system, the hot air outlets can be installed in the same room as the fireplace, or one or both of the outlets can be installed in adjacent or upper rooms. Installing the ducts at dif- ferent elevations will tend to exhaust more heat out of the higher outlet (Figure 17).
  • Page 12: Outside Air Kit

    OUTSIDE AIR KIT It is mandatory to install an outside air connection to the Montecito Estate™. The following components are required and are included with the fireplace: - Outside air kit (includes 40 inch flex that goes up to ten (10) feet long) - 4”...
  • Page 13: Chimney System

    THE CHIMNEY SYSTEM Chimney Installation Notes 1. If possible, install an interior chimney as it will provide better per- formance. In areas with continuous temperatures below 18°C (0°F), the use of an exterior chimney increases the likelihood of operating problems such as low draft, high rate of creosoting, and poor start-up characteristics.
  • Page 14: Chimney Installation Instructions

    CHIMNEY INSTALLATION INSTRUC- TIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 22). Use a plumb bob to line up the center of the holes. The sizes are indicated in Table 2 for the floor and ceiling holes and Table 3 (Page 15) for the roof holes.
  • Page 15: Offset Chimney Installation

    CHIMNEY MODEL ACBI Chimney Collar Flashing Figure 25 Roof Down Slope Hole Size DEGREE OF SLOPE Secure Temp™ S2100+ Nova Temp™ HT6000+ Secure Temp GX Roof Pitch 7” 15” (380 mm) 2/12 15-3/8” (390 mm) 4/12 16-1/8” (410 mm) 6/12 16-7/8” (430 mm) 8/12 18-1/4”...
  • Page 16 Chimney Elbow Offset & Height 8” 3” (76 mm) 15º 20-3/4” (527 mm) S2100+ 7-1/2” HT6000+ (191 mm) 30º 7” 16-1/2” (419 mm) 10” 45º (254 mm) Canada 17-9/16” Only (446 mm) Chimney Elbow Offset & Height ---- ---- 15º ---- ---- ACBI...
  • Page 17 Figure 28 OFFSET CHIMNEY INSTALLATION WITH WALL PENETRATION Rain Cap Outside Wall Framing 2” x 3” Figure 29 OFFSET CHIMNEY INSTALLATION Support Straps Chimney ACBI ACBI Starter Section Insulated Wall Radiation Shield NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Straps Collar Roof Support Roof Flashing Offset Support...
  • Page 18: Angled Wall Radiation Shield

    ANGLED WALL RADIATION SHIELD (XRSMI30 and AC10RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. Note: 45º angle for Canada only (XRSMI45). In cold climate locations (climates where temperatures will fall below 32º F / 0º...
  • Page 19: Masonry Application Instructions

    INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION WARNING: Before starting the installation, the masonry chimney must be inspected by a qualified chimney sweep. The following requirements must be respected: 1. The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing bricks that could inhibit correct installation of the liner.
  • Page 20: Installation Accessories

    OPTIONAL INSTALLATION ACCESSORIES Installation Accessories Description Facades (Required - Order Separately) Montecito Estate™ Facade Black, MEFBK Montecito Estate Facade Brushed Nickel, MEFBN Montecito Estate Facade Hammered Steel, MEFMC Doors - (Required - Order Separately) Montecito Estate Doors Black, MECBK Montecito Estate Doors Brushed Nickel, MECBN Montecito Estate Doors Hammered Steel, MECMC Outside Air Kit (included with fireplace) Outside Air Coupler To Connect Outside Air (UZI) To Fireplace, UZIAD...
  • Page 21 CHIMNEY - PARTS AND COMPONENTS LISTS ACBI Chimney* (7” I.D., 13” O.D. AC - Air Cooled) * AC Chimney is NOT recommended at elevations above 4,000 feet or in cold climates (climates where temperatures will fall below 32° F / 0° C). Description One of the following adaptors is required if installing an AC chimney system...
  • Page 22: Replacement Parts

    REPLACEMENT PARTS LIST Montecito Estate™ - Replacement Parts Description Blower Blower Motor Speed Control Snap Disc, Blower Baffle refractory (2 pieces) (top of firebox) Top Hearth Insulation Front Refractory Bricks Back Refractory Brick Right Side Refractory Bricks - Back Right Side Refractory Bricks - Front Left Side Refractory Bricks - Back Left Side Refractory Bricks - Front Bottom Refractory Brick...
  • Page 23: Clearances

    NOTES...
  • Page 24: Warranty

    REMEDY AND EXCLUSIONS The coverage of this Warranty is limited to all components of the fireplace system, stove or insert manufactured by LHP, with the exception of optional LHP tempered glass doors. A separate limited warranty is available from LHP for optional glass doors manufactured by LHP. Ceramic glass doors manufactured by LHP are warranted against thermal breakage only.