Lennox MONTECITO ESTATE MONTEST Installation And Operation Instructions Manual

Epa wood-burning fireplace
Hide thumbs Also See for MONTECITO ESTATE MONTEST:

Advertisement

Quick Links

SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
A French manual is available upon request. Order P/N 850038CF.
Ce manuel d'installation est disponible en francais, simplement en faire
la demande. Numéro de la pièce 850038CF.
• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• If small children are present in the home, it is
recommended that this appliance be fitted with
an adjustable safety gate or barrier screen.
WARNING
Listed to standards:
ULC-S610 and UL-127
Report No. 304-7213
EPA Cert. No. 609
PIMONTEST REV. 11 05/2013
INSTALLATION AND

OPERATION INSTRUCTIONS

MONTECITO ESTATE™
EPA Wood-Burning Fireplace
P/N 850038M REV. L 05/2013
MODEL
MONTEST
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and
understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circum-
stances. Any modification or alteration of the fireplace system, including
but not limited to the fireplace, chimney components and accessories,
may void the warranty, listings and approvals of this system and could
result in an unsafe and potentially dangerous installation.
IHP wood-burning fireplaces are designed for use as a supplemental
heater. They are not intended for continuous use as a primary heat
source.
• The fireplace cannot be operated without a door
or firescreen. Consult your dealer to select the
correct replacement door or firescreen.
• The fireplace is equipped with a blower, electri-
cal connection must be made prior to fireplace
installation
• Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
• Install the fireplace only as described in these
instructions.
WARNING

Advertisement

Table of Contents
loading

Summary of Contents for Lennox MONTECITO ESTATE MONTEST

  • Page 1: Operation Instructions

    INSTALLATION AND OPERATION INSTRUCTIONS MONTECITO ESTATE™ EPA Wood-Burning Fireplace P/N 850038M REV. L 05/2013 MODEL MONTEST This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation. Do not alter or modify the fireplace or its components under any circum- stances.
  • Page 2: Safety Rules

    IMPORTANT! GENERAL SAFETY WARNING WARNING PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY Use care when selecting window Never leave children unattended RULES BEFORE YOUR FIRST FIRE. treatments for windows located when there is a fire burning in near the fireplace. Avoid using the fireplace.
  • Page 3: Table Of Contents

    CONGRATULATIONS! OPTIONAL EqUIPMENT - AC Chimney Adaptor When you purchased your new fireplace, you joined the ranks of thousands of individuals (required if using AC Chimney whose answer to their home heating needs reflects their concern for aesthetics, efficiency - AC Chimney Outside Air Kit and our environment.
  • Page 4: Combustion Control

    First Fires right. The primary air is fully opened when the Before using the fireplace make sure to remove air control is completely moved to the left. This the plastic wrapping and EPA label on plated air combustion control should be in the closed door.
  • Page 5: Refueling For Best Performance

    B. Open the doors about 1” and wait 5 seconds G. Poor chimney draft until the air flow has stabilized. Then open With no fire, there should be sufficient draft the doors completely, put the logs in and to exhaust cigarette smoke introduced under close the doors.
  • Page 6: Chimney Maintenance

    Chimney Maintenance DOOR INSTALLATION WARNING Regular chimney inspection and maintenance The doors must be put in place only when the Disposal of Ashes: Ashes should combined with proper operation will prevent installation of the Montecito Estate™ fireplace chimney fires. Keep your chimney clean. Do not is completed.
  • Page 7: Glass Care - Replacement

    DO NOT USE CHEMICAL GLASS CLEANERS ON PAINTED SURFACES AS WARNING IT MAY CAUSE THE PAINT TO PEEL. CAUTION : DO NOT ALLOW WINDOW CLEANER TO GET IN CONTACT • Use only a IHP glass doors, specifically designed WITH DOOR GASKET OR PAINT ON FACADE OR DOOR. ONCE CLOSED, for the Montecito Estate™...
  • Page 8 When selecting the location, the chimney outlet position and the direction of the wind are important factor affecting the chimney performance. To allow a maximum draft and to reduce wind turbulence, the chimney must: • Penetrate the highest part of the roof. •...
  • Page 9: Facade Installation

    Facade Installation The crack between the fireplace Install the Facade per instructions provided in Hearth Extension and the hearth extension must be Facade Kit (ordered separately - see Page 21). Non-Combustible sealed with a non-combustible Finish Material Framing, Facing And Mantel material such as sand-cement (i.e.
  • Page 10 CORNER Combustible materials can NOT be used in the space directly INSTALLATION above the fireplace. Do not fill the space above the fireplace with any material (Except the wood framing) 29-1/2” Header 2” x 3” Min. 23-3/4” Plywood 1/2” Back Wall of Chase/Enclosure OUTSIDE CHASE Including Finising Materials if any Fireplace Framing...
  • Page 11: Nailing Flanges

    Same As Ceiling Drywall or Any Rigid Material Draft Stops 2” x 4” Insulated Chase Construction Mantel and Facing 1/2” Plywood Storm Roof Support (Side View) Collar Firestop Flashing Attic Mantel Drywall * Floor Radiation Ceiling * Floor CTDT 2” X 3” Min. Shield Wall Termination...
  • Page 12: Fireplace Blower

    Fireplace Blower When installing the double outlet system, the hot air outlets can be installed in the same room as the fireplace, or one or both of the outlets can be The fireplace comes equipped with a heat activated blower. It is located installed in adjacent or upper rooms.
  • Page 13: Outside Air Kit

    The duct system must be installed respecting the following: Make a 4-1/4” (110 mm) hole in the outside wall of the house at the chosen location. From outside, place the outside air register in the hole (open 1. Remove the plates closing up the 8” diameter holes on top of the side down) and fasten the register to the wall with screws as shown (see fireplace.
  • Page 14: Chimney System

    THE CHIMNEY SYSTEM NOTE: 2" clearance to combustibles around chimney components required. Chimney Installation Notes NOTE: Blown or fill type insulation materials must not be in contact with the fireplace or in the enclosure frame as described in ‘’Enclosure’’ section. 1.
  • Page 15: Chimney Installation Instructions

    S2100 / HT6000+ ACBI Solid Packed Pipe * Air Cooled Pipe * Attic Radiation Shield Attic Radiation Shield Figure 21 2. From below, install a firestop in each ceiling/ floor separation through which the chimney will pass. At the attic level, install an attic radiation shield from above (Figures 22a Radiation Shield and 22b).
  • Page 16: Offset Chimney Installation

    After reaching the location requiring the CHIMNEY MODEL ACBI * elbow, proceed as follows: Chimney Secure Temp ® S2100+ / Nova Temp ® HT6000+ Collar / Secure Temp GX Chimneys 1. Install the first elbow; turn it in the required direction.
  • Page 17 Offset Dimensions Total Height Horizontal Offset Chimney Elbow Offset & Two Lengths Between Elbows Height 8” 12” 18” 24” 36” 8” & 36” 12” & 36” 18” & 36” 24” & 36” 36” & 36” 3” 4-1/4” 5-3/4” 7-1/4” 10-1/4” 12-1/4”...
  • Page 18 OFFSET CHIMNEY INSTALLATION Support Straps Straps Chimney ACBI ACBI Starter Section NOTE: This illustration is not to scale. It represents how the chimney must be supported. A 30 degree offset only is allowed in the USA and a 45 degree maximum offset is allowed in Canada.
  • Page 19: Angled Wall Radiation Shield

    ANGLED WALL RADIATION SHIELD For roof support installation, refer to the instructions provided with the (XRSMI30 and AC10RSMI30) support. UNIVERSAL OFFSET SUPPORT When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only This support is used to support the chimney above an offset.
  • Page 20: Masonry Application Instructions

    INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION Follow these steps: 1- Position the fireplace in its location. Temporarily install the S2100+ WARNING: Before starting the installation, the masonry chimney elbow on the top of the fireplace and, using a level, mark with an oval must be inspected by a qualified chimney sweep.
  • Page 21: Installation Accessories

    OPTIONAL INSTALLATION ACCESSORIES Installation Accessories Fireplace Kits Description Cat./Part No. Description Cat./Part No. Facades (Required - Order Separately) Rigid firescreen, BTZN BTZN Central Forced Air Kit Accessories H4850 Montecito Estate™ Facade Black, MEFBK Central Forced Air Kit, Central forced air kit including: blower H4852 Montecito Estate Facade Hammered Steel, MEFMC (BISZY), flex adaptor (BISAF), 2 clamps, variable speed...
  • Page 22: Replacement Parts

    REPLACEMENT PARTS LIST SPECIFICATIONS Montecito Estate™ - Replacement Parts Cat. No. Model Description Cat./Part No. H4842 MONTEST Fireplace Blower PR-UZY7 Product Reference Information Blower Motor Speed Control VRUW Weight 450 lbs Snap Disc, Blower Height 49-3/8” Baffle refractory (2 pieces) (top of firebox) PR-ISO2205 Width 46-1/4”...
  • Page 23: Chimney Components Lists

    SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS The components listed below must be ordered from Security Chimneys International™. Contact your Security Chimneys Distributor or Dealer for ordering information. Security Chimneys International Limited 450-973-9999 2125 Monterey, Laval, quebec 1-800-361-4909 (USA) Canada, H7L 3T6 1-800-667-3387 (Canada) www.securitychimneys.com Fireplace Model MONTEST - Approved Venting Components manu-...
  • Page 24 SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS The components listed below must be ordered from Security Chimneys International™. Contact your Security Chimneys Distributor or Dealer for ordering information. Security Chimneys International Limited 450-973-9999 Tubinox™ LL Chimney Lining System 2125 Monterey, Laval, quebec 1-800-361-4909 (USA) Rigid Stainless Steel Liner For Relining A Masonry Chimney, 7”...
  • Page 25 NOTES...
  • Page 26: Product Reference Information

    Consult your local distributor for fireplace code information. LENNOX , the LENNOX design, DAVE LENNOX, the image of DAVE LENNOX and other related ® LENNOX marks are registered or common law trademarks of Lennox Industries Inc. and are used with permission.

Table of Contents