TYPICAL
1. Puller
Tighten puller screw and at the same time, tap on
screw head using a hammer to release magneto
rotor from its taper.
Magneto Housing
To remove magneto housing no. 7, starter has to
be removed. Refer to STARTING SYSTEM.
Unscrew retaining screws no. 8, then withdraw
housing.
68
REMOVE SCREWS
1. Magneto housing
Stator Assembly
Remove holding plate no. 9 and withdraw plug
from cover.
Unscrew bolts no. 10 and remove stator no. 11
from magneto cover.
1. Holding plate
2. Stator assembly
3. Remove screws

CLEANING

Clean all metal components in a solvent.
CAUTION: Clean coils and magnets using only
a clean cloth.