Generating Coil
To replace generating coil no. 12:
– Heat the armature plate to 93°C (200°F) around
the screw holes to break the threadlocker bond.
F00D08A
1. Heat the armature plate
CAUTION: Protect harness from flame.
– Remove screws no. 13.
– Uncrimp and unsolder BLACK/RED wire from
coil.
1. Uncrimp and unsolder wire here
Battery Charging Coil
To replace battery charging coil no. 14:
– Heat the armature plate to 93°C (200°F) around
the screw holes to break the threadlocker bond.
smr2005-076
F00D09A
1. Heat the armature plate
CAUTION: Protect harness from flame.
1
– Remove screws no. 15.
– Uncrimp and unsolder YELLOW and YEL-
LOW/BLACK wires from coil.
– Uncrimp and unsolder ground wire (BLACK)
from coil core.
1. Uncrimp and unsolder ground wire (BLACK)
2. Uncrimp and unsolder YELLOW and YELLOW/BLACK wires

CLEANING

Clean all metal components in a solvent.
CAUTION: Clean coils and magnets using only
a clean cloth.
Clean crankshaft taper and threads using Loctite
chisel (gasket remover) (P/N 413 708 500). Apply
the product on a rag first then clean the crankshaft.
www.SeaDooManuals.net
Section 02 717 ENGINE
Subsection 02 (MAGNETO SYSTEM)