Adjusting positive stops
1
008762
(A)
90
45
45
90
(B)
006157
The tool is equipped with positive stops at 90° and 45° to
the table surface. To check and adjust the positive stops,
proceed as follows:
Move the handwheel as far as possible by turning it.
Place a triangular rule on the table and check to see if
the blade is at 90° or 45° to the table surface. If the blade
is at an angle shown in Fig. A, turn the adjusting screws
clockwise; if it is at an angle shown in Fig. B, turn the
adjusting screws counterclockwise to adjust the positive
stops.
After adjusting the positive stops, set the blade at 90° to
the table surface. Then adjust the arrow pointer so that
its right edge is aligned to the 0° graduation.
1
008763
1. 90 ゚ adjusting
screw
2. 45 ゚ adjusting
screw
2
1. Arrow pointer
Switch action
2
ON
009028
CAUTION:
Before plugging in the tool, always be sure that the
•
tool is switched off.
Switch off the tool and then press in the restart
•
button.
To start the tool, raise the switch lever. To stop it, lower
the switch lever.
Removing the upper yellow part of the switch allows the
tool not to start.
2
009046
Sub table (R)
008765
008766
6
1. Switch
2. Restart button
OFF
1
1. Switch
2. Restart button
3. Upper yellow
part of the
switch
3
1
1. Screws
1
1. Sub table (R)