Typical Installation Sequence - Superior DRT6340TYN Installation And Operation Instructions Manual

Superior drt/drc6300 series powervent direct vent gas fireplaces
Table of Contents

Advertisement

INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS
Step 4. FIELD WIRING
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous
operation.
ATTENTION: Au moment de l'entretien des commandes,
étiquetez tous les fils avant de les débrancher. Des erreurs
de cáblage peuvent entraîner un fonctionnement inadéquat
et dangereux.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adéquatement une fois
l'entretien terminé.
CAUTION: Ground supply lead must be connected to the wire
attached to the green ground screw located on the outlet box.
See Figures 27 and 28 on Page 21. Failure to do so will result
in a potential safety hazard. The appliance must be electrically
grounded in accordance with local codes or, in the absence of
local codes, the (USA) National Electrical Code, ANSI/NFPA
70 - latest edition, or the Canadian Electrical Code, CSA C22.1
- latest edition.
Route Cable
NOTE: Electrical wiring must be performed by a qualified electrician.
• Install the strain relief in the hole provided on the right side of fireplace
for the electrical wiring (see Figure 20).
• Either use the intgrated junction box, or position an electrical junction
box (not provided) within reach of the termination wiring pigtail (see
Figure 23 on Page 21). Route the pigtail to the junction box as the
termination is installed.
• Route 14 gage AWG grounded solid wire Romex
stranded cable (e.g., SJOT) from the fireplace to the newly installed
junction box near the termination. Ensure the cable is safety plated to
prevent damage from framing nails and finish drywall screws. Route
it into the lower control compartment and cut to length before install-
ing the terminals. Install provided hardware on the ends of the cable.
Cable is not provided. The provided crimp terminals are intended for
use with stranded cable. If using Romex, connect per National Electric
Code or local code.
Strain
Relief
14 Gage
Grounded
Romex or
similar
Stranded
Cable
Vacuum
Hose
Snap
Bushing
Wall Switch
Harness
Figure 20 - Routing Wiring
20
• Refer to Figure 25 on Page 21 and install the electrical hardware on
the ends of the cable. Male terminals on the Black and White wires,
and ring terminals on the ground wire.
• Using standard electrical practices and the terminals provided, con-
nect the three wires of the cable to the termination pigtail within the
Electrical junction box. Ensure ground.
• The fireplace end of the cable will be addressed in Connecting The
Power Vent To The Fireplace Control System.
Figure 21 - Vacuum Hose Connection to Probe
or equally-sized
®
Right Side
of Fireplace
Junction Box
Figure 22 - Vacuum Hose Connection to Pressure Switch
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Probe (1 *)
Adaptor Assembly
* See Figure 11 on Page 14
Vacuum Hose
Pressure switch is located
behind the panel on the right
side of firebox
Firebox
Pressure Switch
NOTE: Pressure switch style may vary from that shown.
Hose Clamp (7 *)
Vacuum Hose (2 *)
Pressure Switch
Vacuum Hose

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drc6340tynDrt6345tynDrc6345tyn

Table of Contents