ELECTRONIC WIRING DIAGRAM
(Schematic representation only)
COLOR CODE:
B = Black
BB = Brown w/Black Stripe
BG = Brown w/Green Stripe
BL = Blue
BR = Brown
G = Green
GY = Gray
O = Orange
R = Red
W = White
Y = Yellow
Figure 27 - Electronic Wiring Diagram
Junction Box
Red
Black
Tab Intact
Field Wired
Factory Wired
Figure 28 - Junction Box Wiring -
120 V, 60 hz, 1-phase
22
Main Wire
Harness
Y
BR
G
Note: On models
without pressure
switch, these
connectors are
Y
plugged together.
Air Pressure Switch
Power Vent Only
Step 5. REMOVE THE GLASS DOOR
ASSEMBLY
• Handle this glass with extreme
care! Glass is susceptible to
damage - Do not scratch or
handle roughly.
• Do not attempt to substitute the
materials used on this door,
or replace cracked or broken
glass with any materials other
Tab
Intact
than those provided by the
Hot
appliance manufacturer.
Side
• The glass door of this appliance
must only be replaced as a
complete unit as provided
by the manufacturer. Do not
attempt to replace broken,
Neutral
Side
cracked, or chipped glass
separately.
Green
Ground
Screw
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
885 Valve
Battery Holder with Switch
Battery Holder w/Switch
ON/Remote/OFF
ON/ Remote
/OFF
B
O
R
BL
G
Battery Holder
W
Wire Harness
R
B
BL
R
O
G
B
GR
WH
B
W
G
Power Vent Blower
Power Vent
Models Only
WARNING
IPI Pilot
Pilot Tube
Optional
Split Flow
B
Reset Switch
(See instructions.)
Control Module
Fuse
B
B
Refer to Figure 40 on Page 26 and remove the
front glass door assembly as follows:
Barrier (see Notice, Page 40)
This fireplace comes with a barrier to reduce the
likelihood of burns from touching hot glass. If
the barrier is damaged, the fireplace should be
turned off immediately and the fireplace must
not be operated until a new, approved factory
barrier for this unit is installed.
To remove barrier follow these steps.
A.Lift barrier up by the frame at the top.
B.Remove lower filler piece by pulling down
off of the barrier.
C.Lower barrier and push barrier to left to
release right side.
D.Pull the right side out of fireplace.
E.Remove barrier.
Using a Phillips screwdriver, unfasten the two
(2) screws located at the top of the glass door
assembly.
Tilt the glass door assembly at the top away
from the unit. Lift it carefully off the bottom
door track and set the glass door assembly
aside, protecting it from inadvertent damage.
Flame
Sensor
Spark
Electrode
B
Ground Y
G
W
Main Power Cord