Table Of Contents; General Information; Packaging List; Appliance Specifications - Lennox Hearth Products X-Fires 1000 Installation And Operation Manual

Catalytic vent-free wall-mounted gas fireplace signature collection
Table of Contents

Advertisement

CONGRATULATIONS ON THE PURCHASE OF YOUR NEW
GAS APPLIANCE MANUFACTURED BY LENNOX HEARTH
PRODUCTS.
When you purchased your new gas fireplace, you joined the ranks of
thousands of individuals whose answer to their home heating needs
reflects their concern for efficiency and our environment. We extend our
continued support to help you achieve the maximum benefit and enjoy-
ment available from your new gas fireplace. It is our goal at Lennox Hearth
Products to provide you, our valued customer, with an appliance that will
ensure years of trouble-free warmth and pleasure.
Thank you for selecting a Lennox Hearth Products gas fireplace as the
answer to your supplemental home heating needs.
Sincerely, All of us at Lennox Hearth Products

TABLE OF CONTENTS

Section Contents
1.0
Safety And Warning Information . . . . . . . . . . . . . 2
2.0
General Information . . . . . . . . . . . . . . . . . . . . . . . 3
3.0
Packaging List . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4.0
Appliance Specifications . . . . . . . . . . . . . . . . . . . 3
5.0
Unpacking the Appliance . . . . . . . . . . . . . . . . . . . 4
6.0
Burn-in Period . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
7.0
Codes, Massachusetts & New York . . . . . . . . . . . 4
8.0
Combustion And Ventilation Air. . . . . . . . . . . . . . 5
9.0
Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . 6
10.0
Gas Supply Routes . . . . . . . . . . . . . . . . . . . . . . . 6
11.0
Preparing The Appliance . . . . . . . . . . . . . . . . . . . 7
12.0
Mounting The Appliance . . . . . . . . . . . . . . . . . . . 8
13.0
Fitting the Surround Assembly . . . . . . . . . . . . . . 9
14.0
Checking The Burner . . . . . . . . . . . . . . . . . . . . . . 10
15.0
Connecting A Gas Line . . . . . . . . . . . . . . . . . . . . 10
16.0
Checking The Gas Connections . . . . . . . . . . . . . . 11
17.0
Gas Pressure Check . . . . . . . . . . . . . . . . . . . . . . . 11
18.0
Spark Gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
19.0
Briefing The Customer. . . . . . . . . . . . . . . . . . . . . 12
20.0
Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
21.0
Catalysts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
22.0
Testing For Firebox Leakage . . . . . . . . . . . . . . . . 14
23.0
24.0
Troubleshooting Guide. . . . . . . . . . . . . . . . . . . . . 16
25.0
Replacement Parts List . . . . . . . . . . . . . . . . . . . . 17
26.0
27.0
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
28.0
Product Reference Information . . . . . . . . . . . . . . 20

.0 GENERAL INFORMATION

This appliance is a high efficiency, unvented, flame effect gas heater.
It provides radiant and convected warmth both efficiently and safely
utilizing the latest type catalytic convertor burner technology. The
appliance does not require a flue system of any type as the catalytic
converter cleans the flue products to provide a complete combustion
system, which is intrinsically safe.
These heaters are fitted with a specially designed pilot utilizing an
oxygen depletion sensor (ODS) which responds to the amount of
oxygen available in the room and shuts the heater off before the
oxygen level drops below 18%. It must not be adjusted or put out
of operation. If replaced then manufacturers original parts must be
used. The pilot can be relit only when fresh air is available. Refer to
the Combustion and Ventilation Air section.
The appliance is designed to fit various types of situations as listed
in the Installation Requirements.
This appliance is factory set for operation on the gas type, and at the
pressure stated on the appliance rating plate.
Read all these instructions before commencing installation. All instruc-
tions must be left in the possession of the user for safekeeping.

3.0 PACKAGING LIST

Page No.
Quantity
Description
1
Firebox, burner assembly and wall mounting plate
1
Installation and Operation Manual
1
Warranty Certificate
1
Screw and wall plug pack
1
Rubber grommet
(required - sold separately. see Page 19 for ordering information)
1
Surround Assembly
1
Installation Instruction Sheet

4.0 APPLIANCE SPECIFICATIONS

Gas Type
Gas inlet pressure
Regulator Pressure Setting
Max Energy Input
Min Energy Input
Pilot Energy Input
Burner Pressure
(manifold)
Main burner flow restrictor
(burner orifice)
Oxypilot
Gas Inlet Connection
Ignition
Spark Gap
Please see Data Plate affixed to appliance for current data. This appliance is for use
only with the gas type, and at the pressure stated on the appliance Data Plate.
Table 1
Fireplace
Surround Assembly
X-Fires 1000
Natural Gas
10.5" w.c.
Max.
6" w.c.
Min.
5" w.c.
8,870 BTU/hour
5,110 BTU/hour
560 BTU/hour
3.5" w.c.
High
1.1" w.c.
Low
1.45mm (0.057")
SIT/Bray 908
3/8" NPT at regulator
Piezo spark
1/8" - 3/16"
Propane Gas (LP)
13" w.c.
11" w.c.
10" w.c.
7,500 BTU/hour
5,110 BTU/hour
560 BTU/hour
5.6" w.c.
.9" w.c.
1.03mm (0.04")
SIT/Bray 984
3/8" NPT at regulator
Piezo spark
1/8" - 3/16"
3