Panasonic CS-V18CKE Service Manual page 4

Table of Contents

Advertisement

CS-V18CKE CU-V18CKE / CS-V24CKE CU-V24CKE
Indoor Unit
AUTO
OFF / ON
Automatic Operation Button
• Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
• Press continuously for 5s or < 10s to
operate Test Run/Pump down. "Beep"
sound will be heard at the 5th second.
(Used when test running or servicing.)
• Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. "Beep, beep" sound will
be heard at the 10th second.
Operation Indication Lamps (LED)
POWER
(Green) ........ Lights up in operation,
QUIET
(Orange) ........ Lights up in Quiet
TIMER
(Orange) ....... Lights up in Timer
POWERFUL
ION
(Green)
Operation Mode
• Cooling, Soft Dry, Air Circulation and
Automatic Mode.
Powerful Operation
• Reaches the desired room temperature
quickly.
Quiet Operation
• To provide quiet operation.
blinks in Automatic
Operation Mode
judging.
Mode Operation.
Setting.
(Orange) .. Lights up in Powerful
Mode Operation.
...
.....
.....
Lights up in Ionizer
Mode Operation.
Random Auto Restart Control
• Operation is restarted randomly after
power failure at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Ionizer Control
• Ionizer control for generate negative
Ion in discharge air.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
– Cooling : Fan rotates at Hi, Me and
– Soft Dry: Fan rotates at Lo-speed.
Airflow Direction Control
• Automatic air swing and manual adjusted
by remote control for vertical and
horizontal airflow.
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
7 Minutes Time Save Control
• Cooling Operation only.
Anti-Dew Formation Control
• Anti-Dew Formation Control for indoor
unit discharge area.
4
Lo-speed. Deodorizing
control is available.
Deodorizing control
is available.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-v24ckeCu-v18ckeCs-v24cke

Table of Contents