Μc Decisions Based On Analog Voltages; Continuous Operation Battery Thresholds - Shure SLX2 Service Manual

Shure slx2 wireless handheld transmitter service manual
Hide thumbs Also See for SLX2:
Table of Contents

Advertisement

25A1090 (Rev.3)
This table shows the variant resistor values and resulting voltages at TP_RFBAND for each
band.
RF BAND
H5
J3
L4
R5
S6
P4
Q4
JB
Note: Voltages are calculated with a 3.30V (+/- 0.10V) reference from the power
supplies. If power section supports less than 3.30V, thresholds need to be adjusted.
µC DECISIONS BASED ON ANALOG VOLTAGES
BATTERY_A2D
Measured @ 3V
block battery clips
Note: There is a dead battery lock voltage set at 2.30 Volts. If the transmitter is powered
on with a voltage of less than 2.30 Volts, the system will lock, forcing the user to either
recharge or replace the batteries. During the dead battery lock out, the battery gauge is
empty and the red led flashes.
Rb
1.00k
2.99k
4.99k
7.50k
12.10k
18.2k
30.1k
49.9k

Continuous Operation Battery Thresholds

RF Level
Display
- dBC
- dBC
- dBC
-8 dBC
8
TP_RFBAND(+/- 0.10V)
0.30V
0.76V
1.10V
1.41V
1.81V
2.13V
2.48V
2.75V
Logic
>=
<
<
<
Voltage (V)
2.25
2.25
2.14
2.05