Operation:
[DSLP] button : Switch the displays to "ERROR CORD" and
"ERROR TEMP" (temperature when error
occurred (hexadecimal number)).
[BACK] button : Back to the menu screen.
Error cord:
Error code
00
No error occur
01
Slide open error
02
Angle open error
03
Angle close error
04
Slide close error
05
Slide adjustment error
06
Angle adjustment error
07
Tilt operation error
Temperature error
08
(05h (–40°C) or less, FBh (+140°C) and over)
Time over of open/close operation
09
(over 30 seconds)
3-3-5. ERROR INIT mode
This mode is used to initialize the error history.
In the MECHA mode menu screen, press the [5] button on the remote
commander to start initialize the error history.
3-4. MONITOR1 Mode
Note 1: This mode is used to adjustment of the IC401 on MONITOR board.
(refer to "Section 4 ELECTRICAL ADJUSTMENTS" for details
of adjustments)
Note 2: No change input color system (NTSC/PAL) if press the
[OFF]
button on the remote commander to data save and releasing
this mode. If color sysem is changed or no signal inputed, fault
data is written.
In the ENGINEER menu screen, press the [4] button on the remote
commander to enter the MONITOR1 mode and display as following
figure.
TEST MONITOR1
BRT*** G1 *** COM*** VCO***
CNT*** G2 *** VDN*** CEN***
COL*** WPL*** SHP*** VDP***
HUE*** BPL*** YGA***
When enter this mode, it set the signal format system to NTSC
mode and selects the "VIDEO2" mode automatically.
All operations in this mode are performed using remote control.
The operation of each button in this mode are as following table.
Button
V / v
Select the item
VOL –/+
Change the adjustment value of selected item
DISPLAY
On/off switching of the OSD
Save the adjusted data, and back to the
BACK
ENGINEER menu screen
Detail of error
[BACK]
or
Function
Factory default value of each items:
Display
Setting Item
BRT
Bright
CNT
Contrast
COL
Color gain
HUE
Hue
G1
Gamma 1
G2
Gamma 2
WPL
White peak limiter
BPL
Black limiter
COM
V COM AMP
VDN
V COM DC (for NTSC)
SHP
Sharpness
YGA
Y gain
VCO
VCO free run
CEN
H. CENT
VDP
V COM DC (for PAL)
3-5. MONITOR2 Mode
Note 1: This mode is used to adjustment of the IC401 on MONITOR board.
(refer to "Section 4 ELECTRICAL ADJUSTMENTS" for details
of adjustments)
Note 2: No change input color system (NTSC/PAL) if press the
[OFF]
button on the remote commander to data save and releasing
this mode. If color sysem is changed or no signal inputed, fault
data is written.
In the ENGINEER menu screen, press the [5] button on the remote
commander to enter the MONITOR2 mode and display as following
figure.
TEST MONITOR2
VDN*** RB *** RC *** VDP***
COM*** BB *** BC***
When enter this mode, it set the signal format system to NTSC
mode and selects the "VIDEO2" mode automatically.
All operations in this mode are performed using remote control.
The operation of each button in this mode are as following table.
Button
V / v
Select the item
VOL –/+
Change the adjustment value of selected item
DISPLAY
On/off switching of the OSD
Save the adjusted data, and back to the
BACK
ENGINEER menu screen
Factory default value of each items:
Display
Setting Item
VDN
V COM DC (for NTSC)
COM
V COM AMP
RB
Sub bright red
BB
Sub bright blue
RC
Sub contrast red
BC
Sub contrast blue
VDP
V COM DC (for PAL)
XTL-W7000
Value
90
154
133
125
117
80
125
65
71
83
88
122
128
16
103
[BACK]
or
Function
Value
83
71
135
140
100
180
103
21