Buzzer Test; Key Test - Casio SE-S400 Service Manual

Electronic cash register
Hide thumbs Also See for SE-S400:
Table of Contents

Advertisement

[14] Buzzer Test

[Function]
Tests whether buzzer sounds correctly.
[Operation]
Command : n 0 9 2 k
n: Number of times to run
0
Once (Can be omitted)
1 ~ 9
Infinite loop (To forcibly terminate the test, press the C
• If you select "once", one-shot buzzer sounds.
• If you select "infinite loop", 500-msec intermittent buzzer sounds repeatedly.
[Printout of the Result]
BUZZ
END

[15] Key Test

[Function]
Tests keys.
[Operation]
Command : 9 4 k
• Press any key other than
Display and the Customer Display.
Customer Display
KEY
• Pressing paper feed key will operate the feeder.
(One-printer-type model: l , Two-printer-type model: j and Q)
• Pressing
C
key will terminate the test.
[Printout of the Result]
KEY
ESC
END
SE-S400/PCR-T500/PCR-T520/SE-C450/
SE-S3000/PCR-T2300/PCR-T2400/SE-C3500
92
92
C
KEY and printer feed key; the Key Code is displayed on the Main
Customer Display
← Key Code
088
94
94
– 33 –
key.)
Key Code
Mode Switch No.
10: Hybrid Key
11: Stroke Key

Hide quick links: