Introduction - FireBird Instruction Manual

Firebird smoke exempt inset stove
Table of Contents

Advertisement

1.0 INTRODUCTION

We would like to thank you for purchasing a high efficiency, Firebird Smoke Exempt
Stove (hereinafter referred to as "the inset stove"). The design for this product stems
from our original concept, "the Firebird backboiler". The stove is manufactured in its
entirety in our factory in Baile Mhic Íre, Macroom, Co. Cork, using the highest
standard of workmanship and latest technology.
This instruction manual has been produced for the reference and guidance of qualified
installation technicians.
You should ensure that all installation, servicing and commissioning works are carried
out by a competent person. It should be noted that it is the responsibility of the
installer/householder to ensure that the inset stove is properly commissioned. Failure
to do so may invalidate the warranty.
2.0 IMPORTANT SAFETY NOTES
 The term multifuel refers to commercially available solid fuels such as wood,
smokeless coal and anthracite. The appliance shall not be used as an incinerator;
only recommended fuels shall be used. Liquid fuels should never be used when
lighting or filling the fire.
 Do not store liquid fuels in the close proximity to the inset stove.
 The inset stove is designed in such a way, that under normal burning conditions,
the fumes pass up through the chimney flue and do not escape into the home.
Please ensure that the flue system is checked regularly, that no cracks or openings
are evident and that the seals on the inset stove are in good condition.
 ENSURE THE BAFFLES ARE ALWAYS IN PLACE WHEN LIGHTING THE
INSET STOVE AND NEVER LIGHT A FIRE IF THE BAFFLES ARE NOT IN
PLACE.
 THE INSET STOVE DOOR SHOULD NOT BE KEPT OPEN WHEN THE
FIRE IS LIT/ BURNING.
 The inset stove should never be over stocked/over filled. The draught settings
should be reduced if this occurs.
 A mechanical air supply should never be added to the inset stove.
 The inset stove reaches high temperatures and can be hot to touch. Ensure that
safety guards (in accordance with BS8423:2002) are in place.
 Do not place any furniture or combustible material within 800mm of the inset
stove.
 Please ensure that operating tools are used where provided. The stove becomes
very hot during operation and should not be touched by bare hands.
 Aerosols should not be sprayed near the appliance while alight.
 Ensure the following codes and standards are adhered to:
BS EN 15287 – 1:2007 design, installation and commissioning of chimneys.
-
-
BS EN 12828:2003 heating systems in buildings
-
BS 8303 Code of Practice for the installation of domestic heating and cooking
appliances burning solid mineral fuel.
-
Method of calculation of the design heat load.
3

Advertisement

Table of Contents
loading