Attention must also be given to air
control dampers on this appliance.
Failure to control the dampers
correctly can result in excess smoke.
Please refer to section 5.2 of this
manual for instructions.
6.6.2 Smoke from Appliance
Properly installed, operated and
maintained, this stove will not emit
fumes into the dwelling. Occasional
fumes from de-ashing and re-fuelling
may occur. However, persistent fume
emission is potentially dangerous and
must not be tolerated. If fume emission
does persist, then the following
immediate action should be taken:
1. Open all windows and doors to
ventilate the room.
2. Vacate the premises
immediately
3. Let the fire go out.
4. Check for flue or chimney
blockage and clean if required.
5. Do not attempt to relight the
fire until the cause of the fume
emission has been identified
and corrected. If necessary seek
expert advice.
6. Do not light the fire until the
problem is rectified.
The most common cause of fume
emission is flue way or chimney
blockage. For your own safety these
must be kept clean at all times.
6.7
SERVICING
The following is a guideline checklist
which can be used during servicing.
Note that other checks may be required
(system dependant):
-
Check flue to ensure it is clear and
free from soot.
-
Remove baffles, clean and ensure
they are replaced correctly.
-
Check air supply to room or inset
stove. Ensure that it is clean, secure
and free from debris.
-
Ensure that all seals are in good
condition.
-
Ensure that air wash openings are
clear.
6.8
SPARE PARTS
For spare parts please contact Firebird
directly at the following contact
numbers:
Ireland: +353 (0)26 45253
Northern Ireland: + 44 (0)28 30888330
United Kingdom: +44 (0)1752 691177
7.0 TROUBLE
SHOOTING
FIRE WILL NOT BURN
Check that:
 Primary and secondary air inlets
are open with no obstructions.
 Chimney and baffles are clear.
 Correct fuel is being used. Note
the recommendation is to use good
quality coal. The test results of this
stove have been achieved using
smokeless coal.
 Air supply to room is adequate and
not blocked.
FIRE NOT RESPONDING TO AIR
CONTROLS/OVER BURNING
Check that:
 The door is fully closed.
 Both air controls to the appliance
are fully closed.
 The door seals are in place and in
good condition.
 The correct fuel is being used.