  • Page 1 HEATING SOLUTIONS Multifuel Dry Inset Stove Instruction Manual A st ov e d e s ig n ed f or y o u r c o m fo rt...
  • Page 3: Table Of Contents

    INDEX Page INTRODUCTION ..................IMPORTANT SAFETY NOTES ............... TERMS & CONDITIONS OF WARRANTY ......... INSTAllATION INSTRUCTIONS Performance ..................Health and Safety ................Air Supply ..................Fireplace ..................... Hearth ....................Chimney/Flue .................. Installing and Back Filling ............Checks Before Lighting ..............Commissioning ................
  • Page 4: Introduction

    1.0 INTRODUCTION We would like to thank you for purchasing a high efficiency, Firebird multifuel dry inset stove (hereinafter referred to as “the inset stove”). The stove is manufactured in its entirety in our factory in Baile Mhic Íre, Macroom, Co. Cork, using the highest standard of workmanship and latest technology.
  • Page 5: Terms & Conditions Of Warranty

    (g) Firebird’s prior authorisation must be obtained before examination or repair of the inset stove takes place. (h) Firebird will examine all claims made under the warranty and for any claims deemed invalid, costs incurred will be borne by the householder.
  • Page 6: Installation Instructions

    4.0 INSTALLATION INSTRUCTION PERFORMANCE The following highlights the output and test performance of the inset stove: Firebird 16” Multifuel Dry Inset Stove Fuel Type Wood Ancit Ancit Output to Space - kW Efficiency - % 72.7 74.4 74.2 CO (@13% O 0.79...
  • Page 7: Health And Safety

    The air supply will ensure efficient combustion. Failure to do NOTE: If your Firebird inset stove is not so could result in smoke filling into the installed, operated and maintained room or blackening of glass.
  • Page 8: Fireplace

    Please order a room sealed kit from no less than 4.5 meters, vertically from the Firebird to ensure air tightness is achieved top of the appliance to the top of the chimney, is required. Alternatively, NOTE: Only Firebird’s room sealed kit can...
  • Page 9: Installing And Back Filling

    This avoids possible fire risk. 5. Ensure the stove is fixed to the hearth. There are 4 preformed holes on the Firebird recommend that a thorough side frames of the base to facilitate inspection of the chimney is carried out fixing.
  • Page 10: Checks Before Lighting

    9. All voids must be filled and the flue CHECKS BEFORE lIGHTING pipe flaunched into the chimney, NOTE: Prior to lighting the inset stove, so that no soot can collect when sweeping the chimney. allow sufficient time for the back fill to dry 10.
  • Page 11 Fireplace surround Inset stove Inset facia Fixing screws for 16" inset min 350 mm for 18" inset min 400 mm min 415 to open door limiting dimensions of hearth Typical installation...
  • Page 12: Commissioning

    COMMISSIONING • Welsh Dry Steam Coal (large nuts). Light the fire and check all joints and seals. The above fuels are all suitable for smoke Ensure that fumes and smoke are being control areas. taken up the chimney and no fumes are NOTE: Petroleum coke should never be entering the room. used on this appliance. If used, it will invalidate the guarantee.
  • Page 13: Lighting And Controlling

    lIGHTING AND CONTROllING best results, wood will generally need more secondary air than primary air. 5.2.1 WOOD The following can be used as a starting NOTE: Ensure the baffles are properly base for settings: installed prior to lighting the inset stove as Coal - primary air set on 3;...
  • Page 14: Smokeless Fuel

    5.2.2 SMOKElESS FUEl (under the ash pan) is always replaced The same applies as with wood, but after cleaning. you will require more primary air than secondary air with smokeless fuel. Figure 5. When burning Homefire or Anthracite smokeless fuel, always have the secondary air fully open on ignition.
  • Page 15: Maintenance

    6.0 MAINTENANCE within a month of regular use after installation ClEANING CHIMNEY FIRES When cleaning the glass, always do so If the instructions in this manual are when the inset stove is cold. Abrasive followed and the chimney is cleaned once cleaners or pads should never be used on a year, chimney fires should not occur.
  • Page 16: Servicing

    Ensure that air wash openings types can cause blackening of glass. are clear. Check that: SPARE PARTS • The appliance is not being starved of For spare parts please contact Firebird air. directly on the following numbers: • Bad quality fuel or damp fuel is not being used. Ireland: +353 (0)26 45253 • The balance between primary and Northern Ireland: +44 (0)28 30888330 secondary air is correct.
  • Page 17: Warranty Registration

    8.0 WARRANTY REGISTRATION HEATING SOLUTIONS Please complete the following details and return to Firebird to register your Firebird Multifuel Inset Dry Stove warranty. HOUSEHOlDER INSTAllER Name: Name: ............... ..
  • Page 20 The right is reserved to change specifications, colour, and prices of the models and items illustrated and described in this publication at any time. Whilst every care has been exercised in the production of this catalogue, Firebird cannot accept any liability for errors or omissions. For the latest details always consult Firebird.