Button Test; Dram Test - Lexmark C540n Service Manual

Hide thumbs Also See for C540n:
Table of Contents

Advertisement

5025-2xx, 4xx

Button Test

This test verifies the operator panel button function.
To run the Button Test:
1.
Select Hardware Tests from Diag Menu, and press Select (
2.
Select Button Test, and press Select (
Press count: 0 appears.
Press each operator panel button, and watch to see if the count of button presses increases by one for
each press.
Note: If you press Stop (
Press Stop (

DRAM Test

This test checks the validity of DRAM, both standard and optional. The test writes patterns of data to DRAM to
verify that each bit in memory can be set and read correctly.
To run the DRAM Test:
1.
Select Hardware Tests in Diag Menu, and press Select (
2.
Select DRAM Test, and press Select (
a.
The printer displays:
DRAM Test Testing...
b.
The printer initiates a POR of the printer, and the following screen is displayed:
Resetting the
Printer
c.
After the POR, the printer begins testing the memory.
DRAM Test
P:######
P:###### represents the number of times the memory test has passed and finished successfully.
Initially, 000000 displays with the maximum pass count being 99,999.
F:##### represents the number of times the memory test has failed and finished with errors. Initially,
0000 displays with the maximum fail count being 99,999.
3.
Once the all the memory is tested, the test stops.
To stop the test early, turn the printer off.
3-12
Service Manual
), you end the test.