Adjustment
13
Needle thread tension release
.05.04
Requirement
When magnets 3 are attracted, there should be a distance between the tension disks 4 of
at least 0.5 mm.
2
1
3
0,5 mm
4
Fig. 13 - 12
Adjust tension cable 1 (nuts 2) in accordance with the requirement.