Panel Sensor Pcb Assy - Brother HL-820 Service Manual

Laser printer
Hide thumbs Also See for HL-820:
Table of Contents

Advertisement

(3)
Lift the base plate ASSY and remove the grounding screw.
3.10

Panel Sensor PCB ASSY

(1)
Remove the main shield.
(2)
Remove the M4x12 screw securing the panel sensor PCB ASSY.
Taptite, bind M4x12
Panel Sensor PCB ASSY
Note:

When re-assembling the main shield, ensure that you fit PCB A to underneath the
main shield.

When re-assembling the panel sensor PCB, ensure that you fit the PCB into hook B
and hook C first. Then, fit the two bosses to the PCB and secure the screw.
Fig. 3-17
Main shield
C
Fig. 3-18
Base Plate ASSY
A
B
III-11
Ground wire
Screw pan(washer),
M3.5x6
Low-voltage Power
Supply PCB ASSY
Main shield
Panel Sensor PCB ASSY