(3) Wipe the surface of the photosensitive drum with a cotton swab until the dust
or paper powder on the surface comes off.
Toner cartridge
Caution:
Do not wipe the surface of the photosensitive drum with something sharp. (ball-point
pen etc.)
Use the cleaning liquid which is a 50-50 mixture of ethyl alcohol and pure water.
I-16
Black band
Possible cause
Step
Drum unit
1
Ditto
2
Paper path
Separator
Photo sensitive drum
Fig. 4-4
Check
Is the wire cleaner positioned
at its home position?
Is the corona wire dirty?
IV-15
Cleaning roller
Result
Remedy
No
Return the wire cleaner to its
home position.
Yes
Clean the corona wire.
If the problem still appears
after cleaning, replace the
drum unit.