6-2. Operation Data
Temperature
No. of
condition (°C)
operating
units
Indoor Outdoor
1 unit
2 units
27/19
35/–
3 units
NOTE :
Model of Indoor unit 10 : RAS-M10UKCV-E, 13 : RAS-M13UKCV-E, 16 : RAS-M16UKCV-E
NOTES :
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
(2) Connecting piping condition : 5 meters x 3 units (5m / each unit)
Standard
Combinations
pressure
of indoor units
P (Mpa)
10
—
—
0,92
13
—
—
0,85
16
—
—
0,73
10
10
—
0,96
13
10
—
0,92
16
10
—
0,92
13
13
—
0,92
16
13
—
0,92
16
16
—
0,92
10
10
10
1,04
13
10
10
0,98
16
10
10
0,98
13
13
10
0,98
Surface temp. of
heat exchanger
T1 (°C)
T2 (°C)
11
9
8
10,5 to 11,5
11 to 12
11 to 12
11 to 12
11 to 12
11 to 12
12,5 to 13,5
12 to 13
12 to 13
12 to 13
– 21 –
Fan speed
Indoor Outdoor
42
High
Med.
47
High
High
50
High
High
49
High
High
51
High
High
51
High
High
51
High
High
51
High
High
51
High
High
51
High
High
52
High
High
52
High
High
52
High
High
Compressor
revolution
(rps)
37
57
73
69
78
78
78
78
78
81
89
89
89