4.6 Emergency engine stop

CAUTION
Shutting down from full-load operation may cause hot water to escape from the expansion tank.
Risk of scalding!
• Allow engine to cool down.
• Wear protective clothing, protective gloves, and safety goggles / safety mask.
NOTICE
An emergency stop causes extreme stress to the engine plant.
Risk of overheating, damage to components!
• Initiate emergency stop only in emergency situations.
Emergency engine stop
Item
Emergency stop pushbutton Press EMERGENCY STOP pushbutton.
After emergency engine stop
Item
Switchgear cabinet, opera-
tor station etc. (depending
on manufacturer)
Engine
32 | Operation | MS150117/01E 2014-10
Action
• Engine is stopped by disconnecting the power supply to the ECU;
• Emergency air-shutoff flaps close (if applicable);
• Signalization (e.g. by horn, beacon) is activated.
Action
Press pushbutton for alarm acknowledgment.
• Audible and visual signalization stops.
Manually open emergency air-shutoff flaps (if applicable).
• Switch on ECU power supply