Function menu/Explanation of functions
Drive controller:
If the VarioTec device is being used as a drive controller, the drive
is directly connected to the VarioTec device, in which case external
signals are converted into control commands. Encoding switch 2
must be set to the lower position.
Group controller:
If the VarioTec device is being used as a group controller,
additional group and drive control devices can be connected.
Encoding switch 2 must be set to the upper position.

Selecting roller shutter/awning or venetian blind:

Encoding switch 3 is used to select roller shutter/awning mode
(lower position) or venetian blind mode.
In venetian blind mode, the blind moves in non-maintained
command mode to ensure that the slats are positioned accurately.
Press and hold any control button for more than 1 second to
operate the venetian blind in maintained command mode.
Functions

Manual operation functions

• UP, STOP, DOWN
• Adjustment to intermediate position
• Adjustment to ventilation/reverse position
• Alarm signals

Automatic operation functions

In automatic mode, both manual and external control commands
are executed:
• External automatic control commands
• UP, STOP, DOWN
• Adjustment to intermediate position
• Adjustment to ventilation/reverse position
• Alarm signals
GB-9

Programming menu

Programming
Programming the intermediate position
Prerequisite: The shutter/curtain/blind is in the upper end
limit position.
1. Press and hold the Pos B programming button.
2. Keeping this button pressed, then press the DOWN button
until the desired intermediate position has been reached.
Use the UP or DOWN button to make any necessary
adjustments.
3. Release the Pos B the programming button. The
intermediate position is now stored.
The control light will flash 3 times briefly.
Programming the ventilation/reverse position
Prerequisite: The shutter/curtain/blind is in the lower end
limit position.
1. Press and hold the Pos V programming button.
2. Keeping this button pressed, then press the UP button until
the desired ventilation/reverse position has been reached.
Use the UP or DOWN button to make any necessary
adjustments.
3. Release the Pos V programming button. The ventilation/
reverse position is now stored.
The control light will flash 3 times briefly