Advertisement

Electrical Performance
Measurement
ITEMS
conditions
Adjustment of
Mode:Forward or
recording bias
reverse mode
current
Recording mode
(Reference
Test tape
Value)
TDK-60
Measurement output
termial
:Both recording and
headphone terminals
Adjustment of
Reference frequency
recording and
:1KHz and 8KHz
playback
(REF.:-20dB)
frequency
Test tape
characteristics
TDK-60
Measurement input
terminal
:OSC IN
Reference Values for Electrical Function Confirmation Items
Measurement
Items
conditions
Recording
Forward or reverse
bias
Test tape
frequency
TDK-60
Measurement
terminal : BIAS TP on
P.C. board
Measrrnment methed
1 With the recording and playback
mechanism, load thd test tapes
TDK-60 , and set the mechanism to the recording
and pausing condition in advance .
2 After connecting 100 in series to the
recorder head, measure the bias current
with a valve voltmeter at both of the
terminals
1 with the recording and playback
mechanism, load the test tapes (TDK-60)
and set the mechanism to the
recording and pausing condition in
advance
2 While repetitively inputting the reference
frequency signal of 1KHz and 10KHz from
OSC IN, record and playback the tape.
Measrrnment methed
1 While changing over to and form BIAS 1
and 2, confirm that the frequency is
changed
2 With the recording and playback
mechanism, load the test tape.
(TDK-60 ) , and set the
mechanism to the recording and pausing
condition in advance.
3 Confirm that the BIAS TP frequency on the
P.C. board is 61KHz +/-1KHz
PC-X250
Standard
Adjusting
Values
positions
4.5 A
+/-0.5 A
Output
deviation
between
1KHz and
8KHz
:-1dB +/-2dB
Standard
Adjusting
Values
positions
61KHz
+/-1KHz
1 - 9

Hide quick links:

Advertisement

loading