MTU 12 V 4000 M93 x Operating Instructions Manual page 18

Table of Contents

Advertisement

Electronic Gear Control Unit (GCU), ship-side wall-mounting
Functions:
• Date processing logistics for gear coupling control;
• Input/output signals as well as data transfer to CAN field bus for remote control and ship-side moni-
toring.
Monitoring in engine room
Engine control and monitoring unit (LOP)
Functions:
• Alphanumeric, monochrome LCD display for monitoring of measured values as well as alarms when
limits are violated;
• Pushbuttons for menu control and dimming unit;
• Combined control and display elements for local engine/gear control;
• Flashing light and horn for combined alarm in engine room;
• Interface to CAN field bus for connected, communicating monitoring system components.
SOLAS – Fire safety requirements
All lines with SOLAS-compliant covers for pipe connections, according to MTU standard MTN5233, are
shown below.
Fuel system, fuel lines with fuel pressures exceeding 1.8 bar
1 Fuel line to fuel filter head
18 | General Information | MS150047/04E 2013-07