Contents Page General Information ....................3 1.1. Important safety advice..................3 1.2. Guidelines for the operator ................3 1.3. Transporting the machine ..................3 1.4. Electrical connection..................4 2. Controls………………………………………………………………………………………..4 3. Preparing the Machine ....................4 4. Operation........................4 4.1. Priming and starting the machine...............4 4.2. Using the machine.....................4 4.3.
IMPORTANT BEFORE USE READ THESE INSTRUCTIONS AND RETAIN FOR FUTURE REFERENCE • The power supply cord must be regularly 1. General information The HM 55 litre range of upright carpet soil inspected for signs of damage. • Do not operate the machine with a damaged extraction machines are designed for the efficient cleaning of carpets and upholstery.
Take extreme care when moving the machine up Fig 1 or down steps or stairs. CAUTION – Incorrect lifting techniques may result in personal injury. We advise that the manual handling regulations are followed. 1.4 Electrical connection • Before connecting the machine to the power supply, check that your supply voltage corresponds with that marked on the rating...
• 5 When Cleaning is Finished When solution spray ceases the solution tank is empty. Switch off the machine, empty the 5.1 Draining and Cleaning recovery tank and refill the solution tank. • IMPORTANT – Ensure recovery tank is emptied When the recovery tank is full, empty by whenever solution tank is filled.
• 6 After Sales Service Wrap supply cord around handle ensuring Should you require after sales service please that plug is not trailing on the floor. • contact the supplier from whom you purchased Store extractor indoors in a dry area. •...
• Damage caused by accident, misuse or 7 Guarantee Your product is guaranteed for one year from the neglect, or the fitting of other than genuine date of original purchase, or hire purchase, Truvox parts. • Defects in other than genuine Truvox against defects in materials or workmanship during manufacture.
9 Technical Specification 230 V ~ 50 Hz, Class I construction. Enclosure to IPX4. With 15m supply cord. HM 55/400 Model HM 55/100 HM55/400 Code HM55/100 Voltage Pump power 27.6/400 Pump Pressure Bar / psi 6.8/100 Flow rate l/min Vac hose length 2 x 1200 Vac motor 2 x 1200...
11 Fault Diagnosis Problem Reason Remedy ELECTRICAL SYSTEM No electrical power 1. Defective power cord. 1. Replace 2. Fuse blown. 2. Replace fuse. Unplug any equipment using the same circuit. Switch is turned on. 1. Faulty electrical cable. 1. Replace cable Intermittent power to 2.
Page 10
valve. valve and replace. 2. Loose brass hex nut. 2. Reseal hex and plug. 3. Valve worn or seals worn. 3. Replace worn parts with solution valve repair kit. Pump motor not working. 1. Loose wiring 1. Check and replace connections 2.
Need help?
Do you have a question about the HYDROMIST 55 and is the answer not in the manual?
Questions and answers