Outdoor Unit - Samsung AQV12F2VE Service Manual

Room air conditioner
Hide thumbs Also See for AQV12F2VE:
Table of Contents

Advertisement

4-2 Outdoor Unit

Take care of the electrical shock by contact on the charging parts before the discharg e
after power off. (If takes approximately 2minutes to discharg e . )
No
Parts
1
Common Work &
Ass'y-control Out
4-4
Procedure
1) Loosen the fixing screw and separate the
Handle-Cabi RH.
2) Separate the Cable-Connector Wire from the
Terminal-Block.
3) Loosen six fixing screws and separate the
Cabi-Upper.
4) Loosen four fixing screws from the
Ass'y-Control Out.
5) Separate the Terminal-Housing from the
Ass'y-Control Out.
6) Separate the Ass'y-Control Out from the
outdoor unit.
7) Loosen five fixing screws and separate the
Cabi-Side.
Remark