Samsung AQV09J Series Installation Manual
Samsung AQV09J Series Installation Manual

Samsung AQV09J Series Installation Manual

Split-type air conditioner
Hide thumbs Also See for AQV09J Series:

Advertisement

Split - type Air Conditioner
E
S
F
DB98-27556A(1)
INSTALLATION
MANUAL
AQV09J Series
AQV12J Series
AQV18J Series
AQV24J Series
(Cooling and Heating)

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AQV09J Series

  • Page 1 INSTALLATION MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series Split - type Air Conditioner (Cooling and Heating) DB98-27556A(1)
  • Page 2: Table Of Contents

    Contents  REPARING FOR NSTALLATION Safety Precautions ..........3 ...
  • Page 3: Safety Precautions

    Safety Precautions Keep this installation manual together with the user’s manual in a handy place so that you can find it whenever you need to see it after reading this manual thoroughly.  Make sure to read the following safety precautions carefully before installation. ...
  • Page 4 WARNING  This indicates the possibility of serious injury or death.  The unit should be installed in  Check if the voltage and the  Do not attempt to repair, accordance with the National frequency of the main power move, modify or reinstall Electrical regulations.
  • Page 5: Choosing The Installation Location

    REPARING FOR NSTALLATION Choosing the Installation Location Indoor Unit Outdoor Unit  Where airflow is not blocked  Where it is not exposed to strong wind  Where cool air can be distributed throughout the room  Well ventilated and dustless places ...
  • Page 6: Accessories

    REPARING FOR NSTALLATION Accessories The following accessories are supplied with the air conditioner:  The number of each accessory is indicated in parentheses. Accessories in the Indoor Unit Case Installation Plate (1) Remote Control (1) Batteries for User’s Manual (1) Installation Manual (1) Service Manual (1) Remote Control (2)
  • Page 7: Nstalling The

    NSTALLING THE IR CONDTIONER Fixing the Installation Plate Before fixing the installation plate to the wall or window frame, you must determine the position of the 2.56 inch (65mm) hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit. When facing the wall, the pipe and cable can be connected from the: Right ...
  • Page 8: Installing And Connecting The Assembly Pipe Of The Indoor Unit

    NSTALLING THE IR CONDTIONER Installing and Connecting the Assembly Pipe of the Indoor Unit There are 2 refrigerant pipes of different diameters: The smaller one is for the liquid refrigerant  The larger one is for the gas refrigerant  A short pipe is already fitted to the air conditioner.
  • Page 9: Cutting Or Extending The Pipe

    NSTALLING THE IR CONDTIONER Cutting or Extending the Pipe A 24.6ft (7.5m) pipe is supplied with the air conditioner. (optional) The length of the pipe can be: Model “A” Extended up to “A”  AQV09J 49.2ft(15m) Shortened as required  AQV12J...
  • Page 10: Installing And Connecting The Drain Hose Of The Indoor Unit

    NSTALLING THE IR CONDTIONER Installing and Connecting the Drain Hose of the Indoor Unit When installing the drain hose for the indoor unit, check if condensation draining is adequate. When passing the drain hose through the 65-mm hole drilled in the wall, check the following: 2inch (50mm) less...
  • Page 11: Changing Direction Of The Drain Hose

    NSTALLING THE IR CONDTIONER Changing Direction of the Drain Hose You can select the direction of the drain hose, depending on where you want to install the indoor unit. Detach the rubber cap with the flyer. Screws hole Screw Detach the drain hose by pulling it and turning to the left. Drain hose Insert the drain hose by fixing it into the groove of the drain hose and the outlet of the drain pan.
  • Page 12: Connecting The Assembly Cable

    NSTALLING THE IR CONDTIONER Connecting the Assembly Cable The outdoor unit is powered from the indoor unit through the assembly cable. Model “A” If the outdoor unit is more than 24.6ft (7.5m) away from the indoor unit, you AQV09J 49.2ft(15m) must extend the cable.
  • Page 13: Ompleting The

    OMPLETING THE NSTALLATION Purging the Connected Pipes The outdoor unit is loaded with sufficient R410A refrigerant for a 24.6ft (7.5m) pipe You should purge the air in the indoor unit and in the pipe. If air remains in the refrigerant pipes, it affects the compressor. It may cause reduction of cooling capacity and malfunction.
  • Page 14: Performing The Gas Leak Tests

    OMPLETING THE NSTALLATION Performing the Gas Leak Tests Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate) To check for gas leaks on the...
  • Page 15: Fixing The Indoor Unit In Place

    OMPLETING THE NSTALLATION Fixing the Indoor Unit in Place After checking for gas leaks in the system, insulate the pipe, hose and cables. Then place the indoor unit on the installation plate. To avoid condensation problems, place heat-resistant polyethylene foam separately around each refrigerant pipe in the lower part of the indoor unit.
  • Page 16: Fixing The Outdoor Unit In Place

    OMPLETING THE NSTALLATION Fixing the Outdoor Unit in Place Install the outdoor unit to a stable base to avoid the generation of noise and vibration, especially when installing the unit close to a neighbor. If you install the outdoor unit in a place exposed to strong winds or at a height, fix it to an appropriate support (wall or ground).
  • Page 17: Providing Information For User

    OMPLETING THE NSTALLATION Providing Information for User After finishing the installation of the air conditioner, explain the following to the user: (refer to appropriate pages in the User’s Manual.) How to start and stop the air conditioner How to select the modes and functions How to adjust the temperature and fan speed How to adjust the airflow direction How to set the timers...