Flare Modification - Samsung AQV12F2VE Service Manual

Room air conditioner
Hide thumbs Also See for AQV12F2VE:
Table of Contents

Advertisement

3-2-2(f) Flare Modification
• Tools used
Flare modification procedure
1 ) Cut the pipe using a pipe cutter.
3 ) Insert a flare nut into the pipe and
modifty flare .
Samsung Electronics
Oblique Raughness
Burr
Operating Instructions and Installation
2 ) Remove burrs at the tip of the pipe cut.
Caution : Burrs not removed may result in
leakage of gas.
D
Outer diameter
A
* Unproper flaring
Inclined
Surface
damaged
Pipe
Reamer
A(mm)
ø6.35mm
1.3
ø9.52mm
1.8
ø12.7mm
2.0
Cracked
Uneven
thickness
3-9