Advertisement

Quick Links

Burner Systems:
PET-24(N, P)
PET-30(N, P)
WARNING
If the information in this manual is not
followed exactly, a fi re or explosion may
result, causing property damage, personal
injury, or loss of life.
Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Open a window.
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in the building.
• Immediately call the gas supplier
from a neighbor's phone. Follow gas
supplier's instructions.
• If you cannot reach the gas supplier,
call the fi re department.
Installation and service must be
performed by a qualifi ed professional
installer, service agency, or the gas
supplier.
This appliance is only for use with the
type of gas indicated on the rating plate.
EARTHCORE INDUSTRIES, LLC. • 6899 Phillips Industrial Blvd • Jacksonville, FL 32256
REV 0 - 1001211240
ISO-FLAMES
A Product of Earthcore Industries, LLC
STADIUM BURNER SET
Leave this manual with the appliance.
Retain this manual for future reference.
IMPORTANT: READ THESE INSTRUCTIONS
CAREFULLY BEFORE STARTING
INSTALLATION OF THE LOG SET
The ISO-FLAMES gas log set is to be installed only in
a solid-fuel burning fi replace with a working fl ue and
constructed of noncombustible material. The installation,
including provisions for combustion and ventilation air
must conform with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or the CSA B149.1, Natural Gas
and Propane Installation Code, and applicable local
building codes.
A damper clamp is included to maintain the minimum
permanent vent opening and to prevent full closure of
the damper blade. The chimney damper MUST be
fully opened when burning the log set. The log set is
designed to burn with yellow fl ames; thus adequate
ventilation is absolutely necessary.
To comply with certification, listings, and building
code acceptances, and for safe operation and proper
performance of this log set, use ONLY Earthcore
parts and accessories. Use of other controls, parts,
and accessories that are not designed for use with
ISO-FLAMES gas log sets is prohibited and will void
all warranties, certifi cations, listings, and building code
approvals, and may cause property damage, personal
injury, or loss of life.
*Note: Solid-fuels shall not be burned in a fi replace
where a decorative appliance is installed.
INSTALLER:
CONSUMER:
1
OWNER'S
MANUAL
FOR INSTALLATION IN
SOLID-FUEL BURNING
FIREPLACES*
DESIGN CERTIFIED
to
Vented Decorative Appliance
ANSI Z21.60b-2004
CSA 2.26b-2004
09-191
No. L-A2-285

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PET-24N and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EarthCore PET-24N

  • Page 1 *Note: Solid-fuels shall not be burned in a fi replace where a decorative appliance is installed. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. 09-191 EARTHCORE INDUSTRIES, LLC. • 6899 Phillips Industrial Blvd • Jacksonville, FL 32256 REV 0 - 1001211240 No. L-A2-285...
  • Page 2 *Note: des Plein-carburants ne seront pas brûlés dans une cheminée où un appareil décoratif est installé. EARTHCORE INDUSTRIES, LLC. • 6899 Phillips Industrial Blvd • Jacksonville, FL 32256 REV 0 - 1001211240 No. L-A2-285...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION SPECIFICATIONS DAMPER CLAMP INSTRUCTIONS BURNER PARTS LIST BURNER INSTALLATION GLOWING EMBER & LAVA COAL PLACEMENT LOG PARTS LIST LOG PLACEMENT INSTALLING/REPLACING BATTERIES LIGHTING INSTRUCTIONS CLEANING AND SERVICING FLAME DESCRIPTION TROUBLESHOOTING CUSTOMER SERVICE & WARRANTY WARRANTY CARD REV 0 - 1001211240 No.
  • Page 4 L'INFORMATION DE SÛRETÉ IMPORTANTE DE PRÉINSTALLATION ET DE CHEMINÉE ATTENTION: L'installation et la réparation doivent être faites par un NFI certifi é ou tout autre installateur professionnel qualifi é. Installateur: Lisez soigneusement ces instructions avant d'installer ce système de brûleur à gaz. Soyez sûr que vous comprenez tous les mesures de sécurité...
  • Page 5: Important Pre-Installation And Fireplace Safety Information

    IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION CAUTION: Installation and repair must be done by an NFI Certifi ed or other qualifi ed professional installer. Installer: Carefully read these instructions before installing this gas burner system. Be sure you understand all safety precautions and warnings contained in this manual. A.
  • Page 6: Specifications

    SPECIFICATIONS ISO-FLAMES gas log sets must be installed only in a wood burning fi replace with the minimum fi rebox dimensions and venting requirements met (see table on this page). This appliance is designed to burn with yellow fl ames; adequate ventilation is absolutely necessary. Minimum Fireplace Size BTU Rating Burner...
  • Page 7: Burner Parts List

    BURNER PARTS LIST Heat sensor Pilot Electrode 24" Model Shown Note: Photos not to scale Replacement parts can be ordered Bottom view from your local Earthcore dealer. ITEM DESCRIPTION ITEM DESCRIPTION Base assembly with burner and grate Flex connector Pilot assembly...
  • Page 8: Burner Installation

    BURNER INSTALLATION The ISO-FLAMES gas log set must be installed by a qualifi ed professional service technician. Instructions must be followed carefully to ensure proper performance and full benefi t from the gas log set. Check to be sure the log set is designed and labeled for the type of gas (natural or propane gas) supplied to the fi...
  • Page 9: Glowing Ember & Lava Coal Placement

    GLOWING EMBER & LAVA COAL PLACEMENT GLOWING EMBER PLACEMENT Sprinkle the glowing embers (see LOG PARTS LIST) lightly and evenly over the entire surface of the main burner tray and ember burner bed. Break up any clumps that may embers have developed during shipment.
  • Page 10: Log Placement

    LOG PLACEMENT This instruction contains suggested log placement for the Iso-Flames log set. Some fl exibility is possible in log placement to suit your individual preference provided excessive sooting does not result from fl ames striking the logs too directly (see Important below). The suggested log placement will allow for superior fl ame pattern, appearance, and adequate ventilation.
  • Page 11: Installing/Replacing Batteries

    INSTALLING/REPLACING BATTERIES CAUTION: ENSURE THE UNIT IS CONNECTED TO THE GAS LINE AND HAS BEEN TESTED FOR "D" batteries LEAKS BEFORE YOU INSERT BATTERIES. REMOTE TRANSMITTER BATTERY "AA" batteries To access the battery, slide open the lid found on the back of the remote transmitter.
  • Page 12 INSTRUCTIONS D'ÉCLAIRAGE POUR VOTRE SÛRETÉ, LISEZ AVANT L'ALLUMAGE Avertissement : Si vous ne suivez pas ces instructions exactement, une incendie ou une explosion peut résulter, entraînant des dégats matériels, le dommage corporel, ou des pertes humaines. N'employez pas cet appareil si n'importe quelle partie a été sous-marine. Réclamez immédiatement un technicien qualifi...
  • Page 13: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING Warning: If you do not follow these instructions exactly, a fi re or explosion may result, causing property damage, personal injury, or loss of life. Do not use this appliance if any part has been underwater. Immediately call for a qualifi ed professional service technician to inspect the appliance and to replace any part of the control system and any gas control that has been underwater.
  • Page 14: Cleaning And Servicing

    CLEANING AND SERVICING Note: Regular cleaning and servicing will be necessary to ensure proper pilot operation and proper burn characteristics. Always shut off the gas to the appliance while performing service work. Allow the appliance to cool before servicing. Installation and repair must be done by an NFI Certifi ed or other qualifi ed professional service technician.
  • Page 15: Troubleshooting

    TROUBLESHOOTING POSSIBLE CAUSE SOLUTIONS BURNER SHUTTING DOWN DURING OPERATION A. Insuffi cient or excessive gas A1. Check gas pressure (check with local gas company). pressure A2. Other gas appliances may be on the same gas line, dropping gas pressure to log set. Check pressures with everything operating to ensure adequate pressure.
  • Page 16 TROUBLESHOOTING (Cont.) POSSIBLE CAUSE SOLUTIONS SOOTING A. On logs, in fi rebox, or room A. Check gas pressure (check with local gas company). B. Drafts in room B. Eliminate drafts by closing heating and air conditioning vents, returns, and outside air vents. Fans blowing directly into fi...
  • Page 17: Customer Service & Warranty

    Earthcore Industries, LLC authorized dealer or call us directly at 800 642-2920. It is important for you to register your ISO-FLAMES gas log system with Earthcore. Please complete the warranty card included in this manual on the following page.
  • Page 18: Warranty Card

    WARRANTY CARD Please cut along dashed lines and send to: Earthcore Industries, LLC 6899 Phillips Industrial Blvd. Jacksonville, Fl 322 56 Attn: Technical Department Warranty Card Date of Purchase: _________________________________________________________________ Name: _________________________________________________________________________ Address: _______________________________________________________________________ City, State: ______________________________________________________________________ Phone No.: ______________________________________________________________________ Gas Log Burner Size: 24”...

This manual is also suitable for:

Pet-24pPet-30nPet-30p

Table of Contents