Isokern® MAXIMUS Linear Series
Open Front Gas Fireplace and Chimney System
Installation, Operation, Maintenance and Owner's Manual
IMPORTANT: This manual contains assembly rules, installation steps and guidelines, and use and maintenance instructions
for Isokern MAXIMUS Linear Series Open Front gas appliances. This manual must become the property of and be reviewed
by all current and future users of this product. It is the responsibility of the distributor, general contractor, and the installer
of this product that the instructions in this manual are followed exactly and, further that the allowed gas log appliance used
in this product be installed in strict accordance with the gas log manufacturer's listing and explicit installation and operation
instructions.
Be Sure to Read Entire Manual Before Beginning Construction.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warning exactly could
result in serious injury, death, or property damage.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IFYOU SMELL GAS
• Do not try to light any appliance.
• Leave the building immediately.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
THESE FIREPLACES ARE DESIGNED FOR USE WITH:
Isokern Models: 82L48, 82L72, 82L96 & 82L120
A PRODUCT OF EARTHCORE® INDUSTRIES, LLC
INSTALLER: Leave this manual with the appliance
CONSUMER: Retain this manual for future reference
Contents of this manual may change without prior notification.
PROPANE (LP) OR NATURAL GAS (NG), ONLY
THIS MANUAL CAN ONLY BE REPRODUCED IN ITS ENTIRETY
Do not install the Isokern MAXIMUS Linear Series
Gas Fireplace in a manufactured home or mobile
home or recreational vehicle.
This appliance complies with National Safety and
is tested and listed to ANSI/CSA Z21.50 – 2019 as
vented gas fireplaces.
Installation must conform to local codes. Check
local codes prior to installation. In the absence of
local codes, installation must conform with
current National Fuel Gas Code, ANSI Z223.1.
PFS Report No. F19 -161
USA: ANSI Z21.50 - 2019
ICC Report No. ESR - 4873
Issued: December 2021
Revision: 001
©2021 Earthcore Industries, LLC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Isokern Maximus Linear 82L48 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EarthCore Isokern Maximus Linear 82L48

  • Page 1 Installation, Operation, Maintenance and Owner’s Manual Isokern Models: 82L48, 82L72, 82L96 & 82L120 A PRODUCT OF EARTHCORE® INDUSTRIES, LLC IMPORTANT: This manual contains assembly rules, installation steps and guidelines, and use and maintenance instructions for Isokern MAXIMUS Linear Series Open Front gas appliances. This manual must become the property of and be reviewed by all current and future users of this product.
  • Page 2: Table Of Contents

    Glass Media Options ............67 MFD – Vertical Termination Installation ......35 Registration Card ............... 68 RS Fan Vertical Termination Installation ......36 The latest revision of this manual may be obtained at the Earthcore website: https://www.earthcore.com/installation-manuals/ Scan this QR code...
  • Page 3: General Information

    The Isokern Maximus Linear Series Open Front and its approved components are safe when installed according to this installation manual and when operated as recommended by the manufacturer. Unless you use Earthcore Industries, LLC approved components tested for this appliance, you may cause a fire hazard or serious injury. Before you begin the installation of this appliance, read these instructions completely.
  • Page 4: Safety Instructions

    These include pregnant women, people with heart or lung diseases or anemia, people at high altitude or under the influence of alcohol. Earthcore Industries strongly recommends the use of a carbon monoxide detector/alarm device wherever gas fired appliances are in use.
  • Page 5 Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Safety Instructions 11) Do not use the Isokern Maximus Linear Series fireplace to cook food or burn paper or other objects. 12) Do not use any solid fuels - wood, coal, paper, cardboard, etc. - in this fireplace. Use only the gas type listed on the fireplace’s burner rating plate.
  • Page 6: Isokern Maximus Linear Series 48" Open Front (82L48)

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Isokern Maximus Linear Series 48” Open Front (82L48)
  • Page 7 Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Isokern Maximus Linear Series 48” Open Front Components (82L48) Component Part# Description Component Part# Description Smoke Dome-48 Backwall (Qty: 2) (Qty: 2) Magnum Base Smoke Dome Side Wall Plate-48...
  • Page 8: Isokern Maximus Linear Series 72" Open Front (82L72)

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Isokern Maximus Linear Series 72” Open Front (82L72) Steel angle: 6” x 6” x 1/2” cut to span firebox opening. This item is not included in the components and can be sourced locally...
  • Page 9 Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Isokern Maximus Linear Series 72” Open Front Components (82L72) Steel angle: 6” x 6” x 1/2” cut to span firebox opening. This item is not included in the components and can be sourced locally...
  • Page 10: Isokern Maximus Linear Series 96" Open Front (82L96)

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Isokern Maximus Linear Series 96” Open Front (82L96) Steel angle: 6” x 6” x 1/2” cut to span firebox opening. This item is not included in the components and can be sourced locally...
  • Page 11 Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Isokern Maximus Linear Series 96” Open Front Components (82L96) Steel angle: 6” x 6” x 1/2” cut to span firebox opening. This item is not included in the components and can be sourced locally...
  • Page 12: Isokern Maximus Linear Series 120" Open Front (82L120)

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Isokern Maximus Linear Series 120” Open Front (82L120) Steel angle: 6” x 6” x 1/2” cut to span firebox opening. This item is not included in the components and can be sourced locally...
  • Page 13 Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Isokern Maximus Linear Series 120” Open Front Components (82L120) Steel angle: 6” x 6” x 1/2” cut to span firebox opening. This item is not included in the components and can be sourced locally...
  • Page 14: Required Clearance To Combustibles

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Required Clearance to Combustibles IMPORTANT: “Combustibles” are defined as “normal construction materials” such as: wood framing materials, particle board, mill board, plywood paneling, plywood sub-flooring and wood flooring. The Maximus Linear Series Open Front fireplaces and chimney systems are tested and listed for installation with “clearance to combustibles”...
  • Page 15: Calculating Flooring Loads

    • Maximus Linear Open Front – 120: @ 131-3/4” x 28” = 25.62 sq. ft. Earthcore is not responsible for structural floor support details for this fireplace system. Unless otherwise noted all floor framing drawings in this manual are merely illustrations to indicate the presence of an underlying floor system. Consult your local structural engineer for proper floor system design, sizing, and specifications.
  • Page 16: Rough Framing Dimensions

    For all “raised hearth” construction - even where concrete blocks are used to create the raised platform, it is still mandatory to use the Isokern base plate. Be sure to Earthcore Adhesive the concrete block platform together. All CMU used for base plate support should be rated ASTM 90.
  • Page 17: General Assembly Instructions

    Earthcore Adhesive is then squeezed from a grout bag onto the contact surfaces of the Isokern components as they are fitted together. NOTE: It is important that a ½” bead of Earthcore Adhesive is piped onto all the components’ contact surfaces, about ½” in from all edges (Figure 7).
  • Page 18: Isokern Maximus Linear Open Front Installation

    1) Apply Earthcore Adhesive to the joints between each baseplate part and ensure to set each base plate in a full bed of Earthcore Adhesive on a level support surface (Figure 9). See page 15 for information regarding the supporting floor system.
  • Page 19 3) Continue assembly of the consecutive courses of the firebox side walls, making sure to stagger the back wall components so that the vertical joints do not align. Apply Earthcore Adhesive to the top of each layer of side wall and back wall components before setting the next course in place (Figure 11).
  • Page 20 When properly installed, the angle iron will protrude ½” beyond the front edge of the side wall components (Figure 12). NOTE: It is not necessary to apply Earthcore Adhesive between angle and Isokern sidewall components. NOTE: The steel angle should not be longer than the width of the firebox.
  • Page 21 Begin by setting the rear Damper Beam components into place. Next, set the Damper End Blocks into place atop the sidewalls in a bed of Earthcore Adhesive. Be sure to apply Earthcore Adhesive to the contact surfaces of each Damper End Block component where it will meet the front and back damper beam lintel components.
  • Page 22 12/2021 Isokern Maximus Linear Open Front Installation 7) Set the rear smoke dome component(s) across the damper beam in a bed of Earthcore Adhesive and flush with the back face of the rear damper beam lintel. Apply Earthcore Adhesive along the top of the front damper beam along its entire length; bead should be 3” from the front edge.
  • Page 23: Assembled Maximus Linear Open Front Units

    Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Assembled Maximus Linear Open Front Units Assembled 48” Maximus Linear Open Front (82L48) Assembled 72” Maximus Linear Open Front (82L72)
  • Page 24 Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Assembled Maximus Linear Open Front Units Assembled 96” Maximus Linear Open Front (82L96). Assembled 120” Maximus Linear Open Front (82L120)
  • Page 25: Combustion Air Kits, Gas & Electrical Line Feed

    Combustion Air Kits, Gas & Electrical Line Feed Access Modification 4” air kits are not required but recommended by Earthcore for the installation of this fireplace. Air kits may help improve fireplace operation in homes that are tightly sealed and with other ventilating appliances installed (Figures 17 and 18).
  • Page 26: B-Vent Metal Chimney - General Information

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 B-Vent Metal Chimney - General Information The Maximus Linear Series Open Front Fireplaces are tested and listed for use only with the specified factory-built metal B- Vent chimney system as detailed in this manual. All Maximus Linear fireplace systems require 12” Metal-Fab Type-B Gas Vent Chimney System with Anchor Plate with Down-Draft Diverter.
  • Page 27: General Venting Requirements

    *Note: Sum of all offsets shall not exceed 180° in a run, with maximum offset angle of 90° per offset Table 1 Contact Earthcore representative for total distances exceeding the table minimums / maximums. Selecting Horizontal or Vertical Venting System With the appliance secured, determine vent routing, and identify the exterior termination location.
  • Page 28 Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 General Vent Systems – Vent Configurations 1) Mount Anchor Plate with Down Draft Diverter: Chimneys for all Maximus Linear fireplace systems must begin with an Anchor Plate with Down Draft Diverter. It is important that the surface of the Isokern chimney has a level surface on which to attach the Anchor Plate.
  • Page 29: General Vent Systems - Vent Configurations

    Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace General Vent Systems – Vent Configurations IMPORTANT: The B-Vent type chimney system must be enclosed within a chase when installed in or passing through a living area where combustibles or people may contact the chimney. This is important to prevent possible personal injury or fire hazard.
  • Page 30: Vertical Termination Systems - Vent Configurations

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Vertical Termination Systems – Vent Configurations NOTE: A B-Vent support plate (MSP) is required if vertical height exceeds 30 feet. Maximum of 30 feet between supports. 9) The vertical vent system will be terminated with a mechanical draft system. Installation instruction for...
  • Page 31: Horizontal Termination Systems - Vent Configurations

    Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Horizontal Termination Systems – Vent Configurations 10) For horizontal terminations, install at least one 12“vertical pipe section on the anchor plate before any elbow installation NOTE: Two 45° elbows may be combined to achieve 90° offset.
  • Page 32: Enervex Rs Chimney Fan & Mfd - General Information

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Enervex RS Chimney Fan & MFD - General Information IMPORTANT: READ THESE INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION. IMPORTANT: EXAMINE ALL COMPONENTS FOR POSSIBLE SHIPPING DAMAGE PRIOR TO INSTALLATION. WARNING!!!: TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1) Use this unit in the manner intended by the manufacturer.
  • Page 33 Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace MFD - General Information The ENERVEX Mechanical Fireplace Damper, MFD, is a low profile, automated fireplace damper. It is for use in conjunction with an ENERVEX ADC100 control and RS model chimney fan as part of the Ecodamper System.
  • Page 34 Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 RS Chimney Fan - General Information The RS Chimney Fan is an end-of-line mounted ventilator that is designed to provide large flue gas volume capacities. It is designed and intended for use with gas-fired fireplaces.
  • Page 35: Mfd - Vertical Termination Installation

    Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace MFD – Vertical Termination Installation Before installing the MFD on the chimney, a power cable should be wired to the actuator and the actuator cover should be secured (Figure 29).
  • Page 36: Rs Fan Vertical Termination Installation

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 RS Fan Vertical Termination Installation Support system for the chimney fan Prior to installation of the chimney fan, it must be assured the chimney can safely carry the weight of the chimney fan.
  • Page 37: Mfd - Horizontal Termination Installation

    Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace MFD – Horizontal Termination Installation Before installing the MFD on the chimney, a power cable should be wired to the actuator and the actuator cover should be secured (Figure 32).
  • Page 38: Rs Chimney Fan - Horizontal Termination Installation

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 RS Chimney Fan – Horizontal Termination Installation To ease installation, detach the fan base by removing the bolts holding the hinges together. Center the fan base over the outlet and bolt the base onto the wall with the hinges pointing upwards.
  • Page 39: Complete Electrical Schematic

    Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Complete Electrical Schematic FIGURE 37...
  • Page 40: Enervex Adc 100 Installation

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Enervex ADC 100 Installation Connection Diagram FIGURE 38 Overall Connection Diagram Notes Power supply shall be from building source power on a dedicated circuit • RS fan wiring shall be dedicated for the fan; branching of the circuit will cause erratic fan behavior •...
  • Page 41: Mfd Wiring

    Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace MFD Wiring Wire that actuator for 2 wire/ 2 position operation as shown in Figure 39 (120 VAC) and Figure 40 (24 VAC) below. The actuator should be set for clockwise (CW) rotation and should fail to 90° (MFD will open).
  • Page 42: Enervex Adc 100 Installation

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Enervex ADC 100 Installation The ADC100 Control Unit must be installed indoors. As shown in Figure 42, the control will be wired directly to a 120/1/60 VAC power supply. The control will also be connected to the fan, appliance, and damper.
  • Page 43 Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Enervex ADC 100 INSTALLATION The probe must be installed between the appliance and the exhaust fan. If a damper is used in the system, the probe should be installed between the appliance and damper.
  • Page 44 Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Enervex ADC 100 Installation ADC 100 Terminal Designation The designations for each terminal on the control board are shown below. Note that Figure 47 only shows the terminals relevant to the Maximus Linear installation. Also shown in this section is a general connection diagram for an ADC100 control system.
  • Page 45: Firebrick Installation - General Information

    (“Split”) for the sidewalls and 2-1/4” thick firebrick (“Full”) on the floor. Thicker firebrick may be used as an option. The pattern for the firebrick lining is an owner option. The ISOSET mortar by Earthcore is to be used when lining the Isokern Fireplace.
  • Page 46 Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Firebrick Installation - Maximus Linear Fireplace 1. Starting approximately 1/2” from the rear of the firebox, FIGURE 48, lay one course of “full” sized firebrick on floor. Ensure a gap of approximately 1/2”...
  • Page 47: Flush Wall Finish Detail

    Isokern firebox. Be sure to fill this gap with Earthcore Adhesive in conjunction with placement of the code required noncombustible finish facing material that is set across the top of the firebox opening.
  • Page 48 Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Clearance to Combustible Trim NOTE: “Clearance to Combustible Trim” are those distances required to ensure that a fireplace mantel or facing will not catch fire. In most cases the distances should also be adequate to prevent any discoloration or warping due to heat.
  • Page 49: Isoflames Linear Burner - Safety Instructions

    Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Isoflames Linear Burner - Safety Instructions WARNING!!!: This appliance assembly contains burner orifices specifically for the input gas specified on the burner and box, as well as the BTU rating specified in this manual. Modifying or failure to use the factory orifice may cause property damage, personal injury, or loss of life.
  • Page 50 Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Isoflames Linear Burner - Safety Instructions 18) It is imperative that the unit’s control areas, burners and circulation air passages be kept clean. 19) Keep all combustible material, gasoline, and other flammable liquids at a safe distance from the fireplace. Do not use the appliance where these items are used or stored.
  • Page 51 These include pregnant women, people with heart or lung diseases or anemia, people at high altitude or under the influence of alcohol. Earthcore Industries strongly recommends the use of a carbon monoxide detector/alarm device wherever gas fired appliances are in use.
  • Page 52: Isoflames Linear Burner - Components List

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Isoflames Linear Burner - Components List NOTE: burner segment shown ② Top view Bottom view TABLE 2 Item No. Description Part Main Burner Assembly (natural gas) ISF-E-36/60/72/96N Main Burner Assembly (propane)
  • Page 53: Isoflames Linear Burner - Specifications

    Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Isoflames Linear Burner - Specifications TABLE 3 Burner Specifications Minimum Fireplace Dimension (in) Width Nat. Gas L.P. Gas Burner Model Depth Height Front Rear High High ISF36LB 17.5 ISF60LB 17.5...
  • Page 54: Gas Line & Valve Box Installation

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Gas Line & Valve Box Installation This appliance must be connected to the gas line in accordance with local codes and/or the National Fuel Gas Code, ANSI Z223.1. After connecting the gas line, all joints in the line and connections at the valve should be checked for leaks before final positioning of the unit.
  • Page 55: Valve Box & Burner Wiring Diagram

    Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Valve Box & Burner Wiring Diagram WARNING!!!: Do not connect 120 VAC to the control valve. The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during and pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
  • Page 56: Burner Installation

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Burner Installation IMPORTANT: Prior to installation: Shut off main gas supply to fireplace. The ISOFLAMES Linear Burner system shall be installed by qualified professional service technician. To ensure proper performance of the appliance the owner’s installation manual must be followed carefully.
  • Page 57 Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Burner Installation 1. Connect all burner segments according to burner model diagram Page 58-60. Make sure all connections are tightly secured. 2. Place burner assembly in center of fireplace floor/cavity.
  • Page 58 Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 36” Burner Connection - ISF36LB For Isokern Maximus Linear 82L48 60” Burner Connection – ISF60LB For Isokern Maximus Linear 82L72...
  • Page 59 Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace 72” Burner Connection – ISF72LB For Isokern Maximus Linear 82L96 ISF72LB Box No. Part No. Qty. E-18BP4 E-18BP5 E-12BP2 E-12BP3 E-BPC...
  • Page 60 Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 96” Burner Connection – ISF96LB For Isokern Maximus Linear 82L120 ISF96LB Box No. Part No. Qty. E-18BP2 E-18BP3 E-12BP2 E-12BP3 E-12BP4 E-12BP5 E-BPC...
  • Page 61: Remote Control System

    Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Remote Control System The Remote allows you to power ON/OFF the fireplace appliance and adjust flame height from the comfort of your chair. It is configured to initialize the ADC100 powering on the fan and damper. Once draft is proved, the ADC100 will allow for burner to operate.
  • Page 62 Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Remote Control System TEMPERATURE INDICATOR DISPLAY With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same time (Figure 66). Look at the LCD screen on the Remote to verify that a C or F is visible to the right of the Room Temperature display (Figure 67).
  • Page 63: Burner Lighting Instructions

    Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Burner Lighting Instructions INSTALLER INSTRUCTIONS It is required that the set of safety instruction labels that have been supplied with the appliance be affixed to the operation and control points of the appliance. It is the installers responsibility to ensure these warnings are properly affixed during installation.
  • Page 64: Full System Initialization

    Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Full System Initialization Once the burner system, MFD, Fan, PDS, and ADC100 have been wired correctly, a full system check is required. Turn ON main gas supply to appliance.
  • Page 65: Troubleshooting

    Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Troubleshooting Earthcore Industries Technical Support: 1-800-642-2920 Probable Issue Possible Solution Cause - Verify power at the switch - Verify wiring connections No power - Verify “POWER” LED on ADC100 is illuminated...
  • Page 66 Earthcore Industries Isokern Maximus Linear Series Open Front Gas Fireplace 12/2021 Troubleshooting ADC100 Alarm Stages Flashes 1 - If damper prove does not close 90 seconds after AUX IN, go into alarm for 30 seconds, followed by a full retry •...
  • Page 67: Glass Media Options

    Earthcore Industries 12/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Glass Media Options Component Part# Description RFG-10-PB 1/2” REFLECTIVE POSEIDON BLUE FIRE GLASS (10 LB JAR) RFG-10-TC 1/2” REFLECTIVE TERRA COPPER FIRE GLASS (10 LB JAR) RFG-10-VB 1/2” REFLECTIVE VESPER BLACK...
  • Page 68: Registration Card

    Registration Card...
  • Page 69 Earthcore Industries 02/2021 Isokern Maximus Linear Series Open Front Gas Fireplace Warranty & Disclaimer Isokern Maximus Linear Series Gas Fireplace ISOKERN offers a Lifetime Warranty for all Isokern components, to be free from defects in materials that negatively affect system performance from the date of purchase, subject to the terms and conditions of this limited warranty.