Chapter 2. Installing and configuring the SAN06B-R

You can install the SAN06B-R in the following ways:
v As a stand-alone unit on a flat surface. For instructions and more information,
v In an Electronic Industries Association (EIA) cabinet using the fixed rack mount
To install and operate the switch successfully, ensure that the following
requirements are met:
v The primary AC input is 100-240 VAC (switch autosenses input voltage), 47-63
v The primary outlet is correctly wired, protected by a circuit breaker, and
v The supply circuit, line fusing, and wire size are adequate, as specified by the
For power supply information, see "Power supply" on page 38.
To ensure adequate cooling, install the switch with the nonport side, which
contains the air intake vents, facing a cool-air aisle.
Verify that the ambient air temperature does not exceed 40° C (104° F) and that the
ambient humidity remains between 20% and 85% while the switch is operating.
This chapter provides the following information:
v "Items included with the switch"
v "Installation and safety considerations" on page 8
v "Setting up the switch as a standalone unit" on page 8
v "Installing in an EIA cabinet" on page 9
v "Cabling and setting up the switch" on page 14
v "Managing license keys (optional)" on page 23

Items included with the switch

The following items are included with the standard shipment of the switch. When
you open the packaging, verify that these items are included in the package and
that no damage occurred during shipping.
Note: If any items are damaged or missing, within the United States and Canada,
v The SAN06B-R switch, containing two combined power supply/fan assembly
v The following rack mount kits are optionally available:
© Copyright IBM Corp. 2009, 2013
see "Setting up the switch as a standalone unit" on page 8.
kit, slide rack mount kit, or the mid-mount rack kit. For more information, see
"Installing in an EIA cabinet" on page 9.
Hz. 200-240 VAC is recommended.
grounded in accordance with local electrical codes.
electrical rating on the switch nameplate.
contact the IBM Quality Hotline toll-free 1-800-442-6773 or direct dial in
other locations: 770-858-8459.
FRUs
– Fixed rack mount kit, with installation instructions
– Slide rack mount kit, with installation instructions
– Mid-mount kit, with installation instructions