ABOUT YOUR WATER HEATER
SAFETY
This water heater is supplied with a thermostat, an over-temperature energy cut-out, temperature sensors, a
pressure relief valve and a combination temperature pressure relief valve. These devices must not be
tampered with or removed. The water heater must not be operated unless each of these devices is fitted and
is in working order.
The operation of the over-temperature cut-out on the thermostat indicates a possibly dangerous situation. If
the over-temperature cut-out operates, it must not be reset and the water heater must be serviced by a
qualified person.
If the electrical conduit to the solar storage tank is damaged, it must be replaced by a qualified person in
order to avoid a hazard. Phone your nearest Solahart Dealer to arrange for an inspection.
Warning: For continued safety of this water heater it must be installed, operated and maintained in
accordance with the Owner‟s Guide and Installation Instructions.
The Solahart warranty may not cover faults if relief valves or other safety devices are tampered with
or if the installation is not in accordance with these instructions.
PRECAUTIONS
Where damage to property can occur in the event of the water heater leaking, the water heater must be
installed in a safe tray. Construction, installation and draining of a safe tray must comply with AS/NZS 3500.4
and all local codes and regulatory authority requirements.
The water heater must be maintained in accordance with the Owner‟s Guide and Installation Instructions.
"Regular Care"
Refer to
on page 10 and to
If this water heater is to be used where an uninterrupted hot water supply is necessary for your application or
business you should ensure that you have back up redundancy within the hot water system design. This
should ensure the continuity of hot water supply in the event that this water heater were to become
inoperable for any reason. We recommend you seek advice from your plumber or specifier about your needs
and building back up redundancy into your hot water supply system.
SOLAR MONITOR
The solar storage tank incorporates a solar monitor. The solar monitor is located on the lower front cover and
houses both a green and a red LED.
The green LED, marked "Solar", indicates the current operational mode of the solar water heater and the red
LED, marked "Attention", indicates a fault mode.
The green LED will emit either a constant glow or a series of flashes, with a 2 second interval between each
series.
The red LED will emit a series of flashes, with a 2 second interval between each series, only if there is a
particular fault condition with the system.
The operational modes are:
Flashes
Operational Modes
solid green
Standby mode
(remains on)
2 x green
Flooding solar circuit
3 x green
Pump flow control
4 x green
Pump flow established
5 x green
Tank at maximum temperature
no green
Call for service
(remains off)
If the power supply to the water heater is on and the green LED is off or the red LED is flashing, this
indicates there is a fault with the water heater. The red LED may emit up to six flashes in each series of
flashes. Count the number of flashes and phone your nearest Solahart Dealer to arrange for an inspection.