Commissioning - Solahart Streamline Owner's Manual

Indirect closed circuit electric boosted solar water heater
Hide thumbs Also See for Streamline:
Table of Contents

Advertisement

TO FILL AND TURN ON THE WATER HEATER
The power supply to the water heater must not be switched on until the solar storage tank is filled
with water.
To fill the solar storage tank with water and turn on the water heater:
Open all of the hot water taps in the house (don‟t forget the shower).
Open the cold water isolation valve fully on the cold water line to the water heater.
Air will be forced out of the taps.
Close each tap as water flows freely from it.
Check the pipe work for leaks.
Open the isolation valve in the pipe work between the outlet of the heat exchanger and the solar pump,
located behind the lower front cover of the solar storage tank (refer to step 4 of
Solar Circuit"
on page 46).
Commission the solar circuit (refer to
Switch on the electrical supply at the isolating switch to the water heater.
The isolating switch must be switched on for the solar controls to operate and solar gain to be achieved.
Set the timer if one is installed (refer to
Explain to the householder or a responsible officer the functions and operation of the solar water heater and
the timer if one is installed. Upon completion of the installation and commissioning of the water heater, leave
this guide with the householder or a responsible officer.

COMMISSIONING

"Solar Circuit"
on page 44).
"Booster Control"
on page 37).
43
"Commissioning the

Hide quick links: