8. Auto White Balance & LV Standard Data Input
Adjust the white balance reference at 3200K, and adjust the normal
coefficient of the light value.
Subject
Clear chart
(Color reproduction adjustment frame)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
3C to 41
Note1: This adjustment should be carried out upon completion of "Color
reproduction adjustments".
Note2: After the power is turned on, this adjustment can be done only
once.
Note3: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1) POWER .................................................................. CAMERA
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu display) ................................... OFF
4) STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
1
0
01
01
2
6
82
01
3
6
16
02
4
5
6
01
11
6
6
01
0D
7
6
02
Note4: The adjustment data will be automatically input to page: F, address:
3C to 41.
Processing after Completing Adjustments
Order Page Address Data
1
6
01
00
2
6
16
00
3
6
82
00
4
0
01
00
5
Procedure
Set the data.
Set the data.
Set the data.
Wait for 2 sec.
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note4)
Procedure
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Set the data.
Set the data.
Perform "Auto White Balance
Adjustment".
5-22