15. Troubleshooting Guide

15.1

Refrigeration Cycle System

In order to diagnose malfunctions, make sure that there are no
electrical problems before inspecting the refrigeration cycle.
Such problems include insufficient insulation, problem with the
power source, malfunction of a compressor and a fan.
The normal outlet air temperature and pressure of the
refrigeration cycle depends on various conditions, the standard
values for them are shown in the table on the right.
Normal Pressure and Outlet Air Temperature (Standard)
Cooling Mode
Heating Mode
Condition: Indoor fan speed = High
Outdoor temperature 95°F at cooling mode
and 44.6°F at heating mode.
Compressor operate at rated frequency
42
Gas Pressure
Outlet air
PSI
Temperature
2
(kg/cm
G)
(°F)
130.53 ~ 174.04
53.6 ~ 60.8
(9 ~ 12)
333.58 ~ 420.60
96.8 ~ 113.0
(23 ~ 29)