Split System Submittal Data
Indoor: CS-E18NKUA
Wall Mounted Heat Pump
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
Circuit Ampacity
Fuse Size, Max.
Compressor
No. used
Output Power
Outdoor Unit
Fan type
Motor Type
Output Power
Airflow
Coil Type
Fin Type - Pipe Type
Rows - F.P.I
Face Area
Indoor Unit
Fan type
No. Speeds
RPM
Motor Output
CFM
(Hi / Med / Lo)
Indoor Sound Rating
Coil Type
Fin Type - Pipe Type
Rows - F.P.I
Face Area
Drain Connection Size
Features
Wireless Remote Controller Standard
Wired Remote Controller ( CZ-RD516C ) Optional
Controls
Remote Controller
Temperature Control
Air Louver
Power Failure Automatic Restart
Self-Diagnosis
Air Filter
Outdoor: CU-E18NKUA
V/PH/Hz
(A)
(A)
DC Rotary Inverter
(W)
DC Motor ( 8 poles )
(W)
CFM
Aluminum ( Blue Coated )
Corrugated Fin
(sq.ft)
(High)
(W)
(Hi) (dB-A)
Aluminum Fin & Copper Tube
Slit Plate - Inner Rifled
(sq.ft)
(in.)
Microprocessor
LCD Wireless Type, Temp, Sensor Built In
IC Thermostat
(Horizontal)
(Vertical)
Washable, Anti-Mold
Approval:
Date:
Construction:
Unit #:
Drawing #:
230/208/1/60
Refrigerant
20
Lbs. - R410a (outdoor unit)
20
Control
Connection
Line Length, Max (ft.)
1
Lift Difference, Max (ft.)
Line Size
Line Size
Propeller
Dimensions
Indoor Unit
Outdoor Unit
Weight
Net
Shipping
Cross Flow
Performance Data @ ARI Standard Conditions (230/208V)
5
Cooling
Total Capacity
SEER
Dehumidification
Amps
Power Inputs
Outdoor Sound Rating
Heating
Total Capacity
HSPF
Amps
Power Inputs
Outdoor Sound Rating
Operating Range
Manual
Cooling
Automatic
Built-In
Heating
Built-In
(in. O.D. Discharge)
(in. O.D. Suction)
(in.)
Height
(Uncrated)
11-7/16"
(Crated)
(Uncrated)
31-5/16"
(Crated)
(lbs.)
(lbs.)
(BTU/H)
(Pints/H)
(A)
(W)
(dB-A)
(BTU/H)
(A)
(W)
(dB-A)
Indoor Air Intake Temp.
Maximum
90F DB/74F WB
Minimum
60F DB/52F WB
Maximum
86F DB/-F WB
Minimum
60F DB/-F WB
R410A
Electronic Expansion Valve
Flare
100
49
1/4"
1/2"
Width
Depth
42-5/32"
9-9/32"
34-15/32"
12-5/8"
Indoor
Outdoor
26
115
17100
18
Indoor / 5.95
Outdoor / 6.60
1300
20400
8.5
Indoor / 7.20
Outdoor / 8.0
1600
Outdoor Air Intake Temp.
115F DB
0F DB
75F DB/ 64F WB
5F DB/-F WB

Advertisement

loading

Summary of Contents for Panasonic CS-E18NKUA

  • Page 1 Split System Submittal Data Indoor: CS-E18NKUA Outdoor: CU-E18NKUA Wall Mounted Heat Pump Job Name: Approval: Location: Date: Engineer: Construction: Submitted to: Unit #: Submitted by: Drawing #: Reference: Power V/PH/Hz 230/208/1/60 Refrigerant R410A Circuit Ampacity Lbs. - R410a (outdoor unit) Fuse Size, Max.