Jydepejsen Trendline 1+2+3 Installation And User Manual

Jydepejsen Trendline 1+2+3 Installation And User Manual

Hide thumbs Also See for Trendline 1+2+3:

Advertisement

Installation and user manual
Trendline 1+2+3
Troja 1+2+3
Softline
Fineline 1+2
Zeus
Athene
Hera
Avanti
Cubic 109-166-215
Cubic Corner
Cubic Wall
Cubic W200
Cosmo Models
- Read this manual carefully and save these instructions
Report # 301-S-02c-4
UL 1482(2010) and S627-00(2000)
Manufactured by:
Ahornsvinget 3-7 DK-7500 Holstebro
T.+45 96101200 F.+45 97425216
Imported by:
PO Box 120 Pound Ridge NY 10576
T.914-764-5679 F.914-764-0465
www.jydepejsen.com
www.wittus.com

Advertisement

Table of Contents
loading

Summary of Contents for Jydepejsen Trendline 1+2+3

  • Page 1 Report # 301-S-02c-4 UL 1482(2010) and S627-00(2000) - Read this manual carefully and save these instructions Installation and user manual Manufactured by: Trendline 1+2+3 Troja 1+2+3 Softline Ahornsvinget 3-7 DK-7500 Holstebro Fineline 1+2 T.+45 96101200 F.+45 97425216 www.jydepejsen.com Zeus Athene...
  • Page 2: Table Of Contents

    Version – 7/12 Contents Description Page Wood-burning stoves from Jydepejsen A/S Before installing your stove Chimney Chimney connector Heat generation and distribution Sensible wood burning Technical information on wood burning Air supply and combustion Preparation for the first fire Lighting the stove...
  • Page 3: Wood-Burning Stoves From Jydepejsen A/S

    1. Wood-burning stoves from Jydepejsen A/S A wood burning stove from Jydepejsen A/S is a quality Danish product. Our stoves have been providing a cheerful, cozy atmosphere and excellent savings on heating in many homes since the company was founded in 1979.
  • Page 4: Before Installing Your Stove

    2. Before installing your stove Jydepejsen stoves Cosmo, Cubic, Trend-linel+2+3, Troja 1+2+3, Soft-line, Fine-line, Zeus, Athene, Hera and Avanti are tested by OMNI-Test Laboratories, Inc. of Oregon and are listed to UL 1482-2010 and ULC S627-2000. They are also EPA certified and meet the more stringent WA State Environmental standards.
  • Page 5 MINIMUM CLEARANCES TO COMBUSTIBLES Description Trendline 1-2-3/ Troja 1-2-3/ Softline/ Cosmo Zeus/ Athene/ Hera/ Avanti/ Fineline 1-2 Cubic 109/166/215/Wall/W200/Corner A. DISTANCE TO SIDE WALL US/CANADA 18" (46 cm) B. DISTANCE TO BACK WALL US/CANADA 10" (25 cm) C. CORNER DISTANCE TO SIDE WALLS US/CANADA 7"...
  • Page 6 DIAGRAMS FOR CUBIC SERIES CUBIC 109/166/215 CUBIC CORNER CUBIC WALL CUBIC WALL CUBIC CORNER...
  • Page 7 Installation of Trendline 2 without the turntable feature If the Trendline 2 stove is to be used without the turntable feature (screws still attached), please follow the standard installation procedures (page 5) under Wall View and Corner View for the correct clearances. Installation of Trendline 2 with the turntable If the Trendline 2 is being used with the turntable feature, first remove the locking screws located under the stove's firebox (as shown below).
  • Page 8: Chimney

    3. Chimney The Jydepejsen stoves must be installed using a Class A UL 103 HT approved factory-built chimney system or a code-approved masonry chimney with a flue liner. In Canada, the installation must conform to NFPA 211 or CAN/CSA-B365, Installation Code for Solid-Fuel- Burning Appliances and Equipment guidelines and methods.
  • Page 9 This prevents any amount of condensed or liquid creosote from running down the outside of the pipe or the stove top. All joints, including the flue collar connection must be secured with three sheet metal screws to ensure that the sections do not separate. For the best performance the chimney connector should be as short and direct as possible, with no more than two 90°...
  • Page 10 Chimney Connector Systems and Clearances from Combustible Walls for Residential Heating Appliances A. Minimum 3.5 in (90 mm) thick brick masonry all framed into combustible wall with a minimum of 12-in (305 mm) brick separation from clay liner to combustibles. The fireclay liner (ASTM 315, Standard Specification for Clay Fire Linings, or equivalent) minimum 5/8 in (16 mm) wall thickness, shall run from outer...
  • Page 11: Heat Generation And Distribution

    5. Heat generation and distribution All Jydepejsen wood-burning stoves are two stoves in one. Inside is the actual stove, produced from strong steel plates, and on the outside a covering of steel, ceramic tiles or soapstone.
  • Page 12: Sensible Wood Burning

    6. Sensible wood burning When dry wood is burned in a wood-burning stove the following process occurs (over a period of approx. 1 hour):  After lighting the log starts to dry and heats up.  After drying the temperature of the wood rises to approx. 300 - 400° F (150 - 200°C) and is converted into volatile gases and charcoal.
  • Page 13: Version

    Remember that three logs will burn just as quickly as one The quantity of firewood determines the heat emission - the more heat you require, the more wood you should add at each refueling. Types of fuel and heating values All the stoves are constructed and approved for burning wood.
  • Page 14: Air Supply And Combustion

    C)) and to keep the glass free of soot. For wood to burn correctly, the right amount of air has to be supplied at the right time and place. In the Jydepejsen DuplicAir system, the startup and primary air are combined into one air supply system.
  • Page 15 There are two other non-adjustable air systems on the stove; secondary air and direct air. Secondary air: To ensure a better combustion of gasses, the stove is constructed with secondary air holes in the baffle plates. Preheated air is supplied through these holes, which ensures burning of the last amount of gases before they slip out through the chimney, even if the primary air has been shut down.
  • Page 16: Preparation For The First Fire

    9. Preparation for the first fire Once your stove is installed and all instructions have been read, the first fire can be started. However, please take careful note of the following: The baking liner should be removed before the initial lighting. A sudden temperature change could cause it to crack.
  • Page 17: Troubleshooting

    12. Troubleshooting Combustion problems can arise if the combustion conditions are not optimal. This can be corrected by following the advice given below. Problem Explanation Remedy  • ■  Open the flue vent.  Insufficient draft The flue vent is closed. ...
  • Page 18: Maintenance Of The Stove

    The heat-reflecting and insulating panels in the firebox of all wood-burning stoves from Jydepejsen are made of vermiculite. This material in its basic form consists of laminated minerals, and is supplied by an ISO 9001 certified company. Vermiculite poses no health hazards.
  • Page 19 Cleaning ceramic tiles Ceramic from Jydepejsen is simple to maintain. Wiping the tiles with a damp cloth is generally adequate. For more stubborn marks, use a little mild soapy water. Like other natural products, ceramic tiles cannot tolerate strong acids or leaching solutions. So, avoid strong detergents.
  • Page 20 Replacing door gaskets (except the Cubic series) 1. Remove the gasket from the inner frame and clean the band mark (it is not necessary to remove the door from the stove). 2. Add a band of heat-resistant glue on the band mark. 3.
  • Page 21: Warranty

    Any claims during the warranty period should be directed to the dealer who sold the stove. All stoves from Jydepejsen come with their own individual serial number on the type plate on the back of the stove. Please quote stove model and serial number to your dealer in connection with service tasks.
  • Page 22 Cubic series - assembly Cubic Wall : The stove must be prepared for either top or rear outlet. Standard construction is rear outlet. Fasten the furnishing on the wall. Place the stove on the lower hooks on the furnishing, tip up the stove and fasten it.
  • Page 23 Cubic W200 : The stove must be prepared for either top- or rear outlet. Standard construction is rear outlet. Fasten the furnishing on the wall. Place the stove on the lower hooks on the furnishing, tip up the stove and fasten it.
  • Page 24 Trendline soapstone - convection...
  • Page 25 Trend-line with full soapstone cladding Soapstone assembling...
  • Page 26 Softline with full soapstone or ceramic cladding Soapstone assembling...
  • Page 27 Softline with full soapstone or ceramic cladding Ceramic assembling...
  • Page 28 Manufactured by: xxxxxxxx Ahornsvinget 3-7 DK-7500 Holstebro T.++45 96101200 F.++45 97425216 www.jydepejsen.com Imported by: PO Box 120 Pound Ridge NY 10576 T. 914-764-5679 F. 914-764-0465 www.wittus.com...

Table of Contents